Siemens Cab equipment/Train overview Flashcards
What is the holding brake pressure?
110KPA
What is the speed threshold for the holding brake on a Siemens?
0.2km
At what speed can’t you apply your spring park brakes?
5km/h
What happens if you apply your spring park brake at that speed and over?
Safety loop de energises, emergency brake goes on
What is the brake pressure for B1?
57KPA
What is the Brake pressure for B6?
189kpa
At what pressure increments does the pressure go up from B1 to B6
26kpa to 27kpa B1-57KPA B2-83KPA = 26KPA B3-109KPA = 26KPA B4 - 136KPA = 27KPA B5 - 162KPA = 26KPA B6 - 189KP = 27KPA
What is emergency brake cylinder pressure?
280KPA
What is the job of a static inverter?
To convert 1500vdc from the pantographs and traction storage into 400vac
Where are the static inverters located?
Trailer cars
How many static inverters per car?
2
What happens if 1 static inverters” becomes defective and inoperative?
HVAC runs at 50% capacity
What happens if both static inverters become defective and inoperative?
Train fails to power
If the safety loop is bypassed, what emergency button is working?
Lead car only
What is the dead mans switch?
Test function for the hand and foot pilot valve
How long is the dead mans switch active?
60 seconds
When is set speed used?
For coupling and low speed shunting movements
What is the set speed limited too?
6km/h and an over speed light comes on
8km/h an emergency brake comes on
What happens when you travel over 119km/h?
Traction is lost and the train cannot accelerate
What happens if you travel over 120km/h
Over speed light illuminated
What happens if you go above 125km/h?
Emergency brake applies
What is a critical defect verbatim?
Critical defects are safety critical failures of the pneumatic friction brake system or a complete loss of Auxillary power (two defective static inverters)
Where is the first aid kit located?
Cabinet top right near b side wall
Where are the ATWs?
Beneath the cabinet