Comeng Faults - Electrics and ROBBDS Flashcards
When would a Local fault light illuminate?
When an overload is tripped in the traction equipment
When would a Line Switch fault light illuminate?
Line breaker has failed to close on a motor car
How would you try to eliminate a local or line switch fault light?
Pressing traction overload reset
What two ways can extinguish a MA light?
Press the Aux start button or traction overload reset
What does a steady air conditioner light mean?
No more then one air conditioner has failed in any one car
What does a flashing air conditioner light mean?
Both air conditioners have failed in any one car
Where is the air conditioning alarm circuit breaker located?
Above door 3 in the saloon areas
Where is the number 2 air conditioner local faul lights located in a motor car?
On the ceiling in the saloon above door 3, 2 end of a motor car
Where is the number 1 air conditioner local fault light in a motor car located?
In the drivers cab above the bulk head door
How do you identify if a spring park brake is stuck on?
Park brake light and this car
How do you lower and isolate a pantograph?
Push Panto Lower Ep Valve
Isolate pantograph ep isolating cock in van area
Isolate pantograph electrical toggle switch
Cut motors out
Submit tmm
What is the first thing to look for when doing a ROBBDS test?
Trips Switches Gauges Cocks Door closed button is illuminated Supply light is on
How would you verify 110vdc is running through the train?
Supply light
Bells work
LP flag is low and ep is operational
What are the six steps for the ROBBDS test?
Reverse Overload Brake pipe Bypass button (control governor) Door loop bypass Second controller
Name the two types of fault types?
Persistent and intermittent