Deck 83 Flashcards

1
Q

(The stretching of “occupant use” hose by who? when operating remotely from an engine company while performing searches, may be justified in an attempt to save lives.)

A

Ladder and rescue companies9.2.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Supplying Standpipe NOTES:-9.3.4 Whenever possible, standpipe systems should be supplied by at least two different pumpers.-9.3.5 Whenever possible, standpipe systems should be supplied through at least two independent siamese connections. If there is only a single siamese connection, a second supply line can be attached to the first floor outlet. Additional floor outlets can be supplied if required.-9.3.7 As a general rule, there should be a separate engine company supplying the standpipe system for each hoseline placed in service.

A

SEE OTHER SIDE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

NOTE: -9.4.12 As the first due engine company begins its advance on the fire, the second due engine must assist with line movement and be prepared at any moment to relieve the first engine company. Air conservation is an important consideration for the second due engine. If it is not possible to conserve air due to smoke and heat conditions, additional engine companies may be utilized by the Incident Commander to reinforce the critical position of the first hoseline.

A

SEE OTHER SIDE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly