Brownstone Cellar Fire First Line

A

First line stretched through the front door on the first floor, then down to the cellar via the interior cellar stairs to extinguish the fire. If the fire has control of the first floor, or the first floor and the cellar, the first line must be stretched to the second floor by way of the outside stairs.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

BrownstoneCellar FireSecond Line

A

Second line stretched above the fire. If the first line was used to secure the stairs, the second line will be stretched to extinguish the fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

BrownstoneCellar FireThird Line

A

as ordered by the IncidentCommander.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

BrownstoneFire on Upper FloorFirst LIne

A

the first line is taken through the front door to the fire floor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

BrownstoneFire on Upper FlooreSecond Line and reasons for stretching

A

Stretched to back up the first line. HEAVY fire condition in this type of occupancynecessitates the use of a second line for the following reasons.1. Protect the advance of the first line.2. Safeguard against burst lengths.3. Quicker extinguishment.4. Less punishment for members.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Brownstone Fire on Upper FloorThird Line

A

it will be stretched as ordered by the IncidentCommander.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Brownstone Fully InvolvedFirst LIne

A

Advanced into the fire building through the front door.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

BrownstoneFully InvolvedSecond Line

A

Back up first line.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

BrownstoneFully InvolvedThird Line

A
  1. If fire is reported in an exposure, stretched to that exposure.2. If there is no fire in the exposures, stretch through an exposure to the rearyard of the fire building.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

BrownstoneTwo Floors of Fire

A

Extra Engine and 15 Truck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Heavy Fire in Cellar and Basement

A

Second Alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The presence of sprinklers in a brownstone may indicate

A

the absence of a fire escape. MOST BROWNSTONES, HOWEVER, DO NOT HAVE FIRE ESCAPES. 2.2.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Sprinkler lines in a brownstone that were further extended into individual rooms would indicate what?

A

The Brownstone was converted to Rooming Houses. 2.2.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

In many buildings, when Brownstones were converted to Multiple Dwellings, what features were added?

A

fire escapes were added or sprinklers were installed in the interior halls in lieu of secondary means of egress.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the interior access to the roof of a brownstone?

A

Access to the roof is via the iron ladder leading up to the scuttle opening.The ladder is usually in a closet. 2.2.16

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the interior access to the roof of a rowframe?

A

there is a scuttle on the roof which is reached by an iron ladder from the top floor. The scuttle isusually near the skylight over the stairs. 5.2.7

17
Q

Some Brownstone buildings may have open stairs in the rear of the building. What floors do they access?

A

They usually go from the first (basement) to second (parlor) floors. 2.3.4

18
Q

Regarding the Queen Anne, what floors does the rear stairs access?

A

A narrow rear or side stair connects the 1st, 2nd and 3rd floors, or a stair may lead directly to the 3rd floor from the 1st floor. PD’s Ch 1 3.3

19
Q

T/F: Brownstone, There may be 2 doors to the small room, one from the interior halland one from a larger adjoining bedroom.

A

True, Consider placing the ladder at theadjoining window to gain entrance to this small room. If there is no door in the small room from the large bedroom, and hallway fire conditions prevent normal entry into the small room, access may be gained by breaking through the lath and plaster partition between the two rooms. Ladders 1, 11.2.2..C.1