Deck 5 Flashcards

1
Q

The major firefighting problem in Fire-Resistive Construction is …

A

The Central Air Conditioning System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What do Fire Dampers stop …

A

flame spread but does not stop the spread of smoke

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

During any fire in a modern building the IC should order the bldg management to …

A

shut the off the central air system serving the living spaces and public hallways.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

FF cannot extinguish fires over how many square feet?

A

5000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the major firefighting problem in Non-Combustible/Limited Combustible Construction?

A

the flat, steel deck roof covering hat can ignite during a fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Regarding non-combustible/limited combustible construction, as soon as the fire is darkened down what should a FF do

A

check the roof covering above the the fluted metal deck for fire extension. As heat may have conducted thru the metal and ignited the combustible roof covering.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Regarding non-combustible/limited combustible construction, as soon as the fire is extinguished what should a FF do?

A

The IC should order a company to the roof to check the the combustible asphalt roof covering

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the major collapse problem in non-Combustible/Limited Combustible Construction?

A

roof cave in from the use of open web steel bar joist. The collapsing material is the UNprotected open web bar joist.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the main advantage of the lightweight steel roof support

A

the non combustibility, the bar joist does not add fuel to the fire.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Metal roofs are not designed to support FF’s during a fire, what type of bldg prohibits open bar joist construction?

A

Hi Rise commercial bldgs since 9/11.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the major fire problem in Ordinary “Brick & Joist” Construction?

A

the fire and smoke spread throughout concealed spaces.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Regarding Brick and Joist bldgs what two tactics does Dunn suggest?

A
  1. As soon as possible after a fire is extinguished, a FF must be directed to open the ceiling above the fire & nearby wall to examine for fire spread within concealed spaces.2. If fire is discovered in a concealed space, the cockloft space above the top floor must be checked for fire before leaving the scene.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is The major fire problem in Heavy Timber Construction

A

The large wooden interior timber framework.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The major firefighting problem in Wood-Frame Construction is

A

the combustible outside wooden walls.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The major collapse hazard in Wood-Frame Construction is

A

the combustible bearing walls composed of 2 x 4 inch studs.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

There are three ways a masonry exterior building wall can collapse:the most common type of masonry wall failure at fires is

A

90-degree angle, curtain fall, inward-outward 90-degree angle is the most common.