Deck 5 Flashcards
The major firefighting problem in Fire-Resistive Construction is …
The Central Air Conditioning System
What do Fire Dampers stop …
flame spread but does not stop the spread of smoke
During any fire in a modern building the IC should order the bldg management to …
shut the off the central air system serving the living spaces and public hallways.
FF cannot extinguish fires over how many square feet?
5000
What is the major firefighting problem in Non-Combustible/Limited Combustible Construction?
the flat, steel deck roof covering hat can ignite during a fire
Regarding non-combustible/limited combustible construction, as soon as the fire is darkened down what should a FF do
check the roof covering above the the fluted metal deck for fire extension. As heat may have conducted thru the metal and ignited the combustible roof covering.
Regarding non-combustible/limited combustible construction, as soon as the fire is extinguished what should a FF do?
The IC should order a company to the roof to check the the combustible asphalt roof covering
What is the major collapse problem in non-Combustible/Limited Combustible Construction?
roof cave in from the use of open web steel bar joist. The collapsing material is the UNprotected open web bar joist.
What is the main advantage of the lightweight steel roof support
the non combustibility, the bar joist does not add fuel to the fire.
Metal roofs are not designed to support FF’s during a fire, what type of bldg prohibits open bar joist construction?
Hi Rise commercial bldgs since 9/11.
What is the major fire problem in Ordinary “Brick & Joist” Construction?
the fire and smoke spread throughout concealed spaces.
Regarding Brick and Joist bldgs what two tactics does Dunn suggest?
- As soon as possible after a fire is extinguished, a FF must be directed to open the ceiling above the fire & nearby wall to examine for fire spread within concealed spaces.2. If fire is discovered in a concealed space, the cockloft space above the top floor must be checked for fire before leaving the scene.
What is The major fire problem in Heavy Timber Construction
The large wooden interior timber framework.
The major firefighting problem in Wood-Frame Construction is
the combustible outside wooden walls.
The major collapse hazard in Wood-Frame Construction is
the combustible bearing walls composed of 2 x 4 inch studs.