Test Prep (incomplete) Flashcards
1
Q
What are Harsh Containment conditions
A
- ≥ 170°F
- 10E8 mr/hr
2
Q
HPSI Throttle Criteria
A
- Lpzr ≥ 10% [15%]
- SCM ≥ 24°F [≥ 44°F]
- One SG available (45-60% NR or restoring)
- RVUH ≥ 16%
- HPSI not needed for boration
3
Q
Natural Circ Indications
A
- Loop ΔT < 65°F
- Tc & Th ↔ or ↓
- ≥ 24°F [44°F] subcooled using CET
- < 30°F ΔT between Thot and max quadrant CET
4
Q
What are the Reduced RCS levels?
A
PLRM - (117 -3, -3, 103)
Partial Drain - 117’
Lowered Inventory - 114’
Reduced Inventory - 111’
Mid-Loop - 103’1”
5
Q
Hot Leg Injection criteria
A
- 2-3 hours after break AND one of the following:
- <24*F [44] REP CET subcooling
- Lpzr <10% [15]
- RVUH <16%
6
Q
Reflux Boiling indications
A
- <44*F [60] CET superheat
- SGWL 45-60% NR
7
Q
Criteria for stopping CSP’s
A
- Stop BOTH if
- on mini-flow
- not expected to be > 8.5psig in 1 hr
- Stop 1 if
- Pcntmt < 50 psig and not rising
- SI actuated and flow in delivery curve
8
Q
SDC entry conditions EOP
A
- < 24°F [44°F] subcooling
- Lpzr > 30% [38%]
- Ppzr < 385 psia
- Thot < 335°F
9
Q
Criteria for using CSP for SDC
A
LPSI criteria AND
- PPZR < 210 psia
- RCS temp < 185°F
10
Q
What is SDC Entry Criteria during a LOCA
A
- LPZR > 30% [38%] and controlled
- ≥ 24*F RCS subcooling
- Ppzr < 385 psia
- Thot < 335°F
- RCS activity will not result in unacceptable doses outside CTMT
CS pump
- Ppzr < 210 psia
- Trcs < 185*F