40AO-9ZZ18 Shutdown outside MCR Flashcards

1
Q

What PPS controls are there on each RSP?

A
  • Low PZR press setpoint reset
  • Low SG press setpoint reset
  • MSIS acutation
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

During 40AO-9ZZ18 Shutdown outside MCR, what are the initial actions PRIOR to leaving CR

A
  • Trip Rx
  • Stop 1 RCP in each loop (can be done from SWGR)
  • Ensure MT tripped

If time permits:

  • PLCS L/A @ 50%
  • LD control and BP vlv switches in BOTH
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the major steps for performing a C/D with 40AO-9ZZ18 Shutdown outside MCR?

A
  • Align CH to RWT (Borate)
  • Feed with AF
  • Trip MFP’s
  • Control SG’s with ADV’s
  • Initiate MSIS
  • Perform C/D
  • Done due to lack of control/ instrumentation for steam plant at RSP
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What C/D rate is established when cooling down with 40AO-9ZZ18 Shutdown outside MCR?

A
  • 60°F/hr
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is performed for MCR re-entry following 40AO-9ZZ18 Shutdown outside MCR

A
  • 1 RO at RSP, 1 RO in CR
  • Perform SPTA’s in CR
  • Transfer ADV to CR
  • Transfer AFA to CR
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What EAL classifications would be used for 40AO-9ZZ18 Shutdown outside MCR

A

Alert:

  • CR evacuation
  • Control of safety functions established in 15 minutes

SAE:

  • CR evacuation
  • Control of safety functions NOT established in 15 minutes

(15 minutes starts when CR evacuated/ CRS leaves)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly