During 40AO-9ZZ22 Fuel Damage, how is the CR informed of NEW fuel damage?
- Fuel Handling Supervisor - cladding wet/dry in CNTMT or fuel bldg penetrated
- Fuel Handling Group - Even occurred with suspected damage
During 40AO-9ZZ22 Fuel Damage, who is notified during a fuel handling event?
- Unit Ops Manager
- Rx Engineering
- Outage Manager
During 40AO-9ZZ22 Fuel Damage, what action is required if a Fuel Handling Event occurs and cladding is NOT breached?
- Place F/A in safe position
- F/A in unanalyzed position could challenge SDM
During 40AO-9ZZ22 Fuel Damage, what action is required if a Fuel Handling Event occurs and cladding IS breached?
- Evacuate non-essential Fuel Bldg and CNTMT
- If Rad lvl allow place F/A in safe position
- RP assess Rad lvls
- E-Plan
In CNTMT:
- CPIAS/CREFAS
- Close Airlocks
- Close Equipment Hatch
In Fuel Bldg:
- FBEVAS/CREFAS
- Ensure = HA supply/exh.
During During 40AO-9ZZ22 Fuel Damage, what additional actions are required for NEW fuel damage vs Irradiated Fuel damage?
- Close Fuel Bldg roll up door
- RP and Rx Engineering pick up fuel pellets
During 40AO-9ZZ22 Fuel Damage, who INITIATES Fuel Handling Event Recovery Checklist?
- RSRO
- Fuel Handling Supervisor (handling issues)
During 40AO-9ZZ22 Fuel Damage, what is considered a “Safe Location” if F/A is:
Above Rx Core
- Designated location in core
- Approved Alternate location in core
During 40AO-9ZZ22 Fuel Damage, what is considered a “Safe Location” if F/A is:
Upender VERTICAL position?
- Lower Upender
During 40AO-9ZZ22 Fuel Damage, what is considered a “Safe Location” if F/A is:
Transfer Canal
- Place in upender in horizontal position
During 40AO-9ZZ22 Fuel Damage, what is considered a “Safe Location” if F/A is:
In Transit b/w Rx and upender?
- Deep area of pool (interlock key)
- Storage rack (not for lowering level)
During 40AO-9ZZ22 Fuel Damage, what is considered a “Safe Location” if F/A is:
Spent Fuel Pool
- SFP storage rack in region with same or lower number
- Deep area of pool lowered just above floor