40EP-9EO02 Reactor Trip Flashcards

1
Q

What is the purpose of 40EP-9EO02 Reactor Trip?

A
  • Actions for UNCOMPLICATED RX TRIP
  • Stabilize in Mode 3
  • Minimize release
  • Transition to appropriate procedure ASAP
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the Entry conditions for 40EP-9EO02 Reactor Trip?

A
  • SPTA’s complete
  • uncomplicated trip (SPTA SFSC’s met)
  • ESD occurred AND MSIS isolated and Tc recovering in SPTA’s
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the Exit conditions for 40EP-9EO02 Reactor Trip?

A
  • uncomplicated reactor trip is NOT confirmed
  • Reactor Trip SFSC acceptance criteria NOT satisfied
  • Procedure is complete:
    • ALL SFSC’s met
    • stable in Mode 3
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

For 40EP-9EO02 Reactor Trip, what is the Rx control SFSC?

A
  • <2x10-4% stable or lowering
  • All FSCEA’s inserted
  • > 40gpm boration
  • SDM verified
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Following a Rx Trip, when is the MAX subcritical multiplication level expected?

A

15 minutes post trip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

For 40EP-9EO02 Reactor Trip, what is the Maintenance of Vital Auxiliaries SFSC?

A
  • At least 1 PB
  • 1 NA & NB
  • At least 1 on same train as PB:
    • PKA, PKC, & PNA
    • PKB, PKD, & PNB
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

For 40EP-9EO02 Reactor Trip, How is the MVA SFSC different than other ORP’s?

A
  • Only ORP that required a non-vital bus
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

For 40EP-9EO02 Reactor Trip, what is the RCS Inventory SFSC?

A
  • Lpzr 10-65% trending 33-53%
  • ≥24°F RCS Subcooling
  • RVLMS 100% RVUH
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

For 40EP-9EO02 Reactor Trip, what is the RCS Press Control SFSC?

A
  • Ppzr 1837-2285 trending 2225-2275 psia
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

For 40EP-9EO02 Reactor Trip, what is the Core Heat Removal SFSC?

A
  • RCS ▲T <10°F

- ≥24°F subcooling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

For 40EP-9EO02 Reactor Trip, what is the RCS Heat Removal SFSC?

A
  • Tc 560-570°F

- At least 1 SG 45-60% NR with feed OR FW restoring to 45-60% NR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

For 40EP-9EO02 Reactor Trip, what is the Containment Isolation SFSC?

A
  • <2.5 psig

- no CNTMT or secondary RU alarms/ unexpected rise in activity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

For 40EP-9EO02 Reactor Trip, what is the CNTMT Temp Press Control SFSC?

A
  • <117°F

- <2.5 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

For 40EP-9EO02 Reactor Trip, what is the basis for the Lpzr upper and lower limits in SFSC?

A
  • 10% Measurable level in PZR

- 65% avoids going solid & steam space for pressure control (spray)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

For 40EP-9EO02 Reactor Trip, what is the basis for the Lsg upper and lower limits in SFSC?

A
  • 45%NR - Ensures tubes are covered

- 60%NR - Ensures margin to MSIS, room for swell

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

For 40EP-9EO02 Reactor Trip, what actions are Unique to Unit 1 during a SIAS signal and why?

A
  • Restore WRF breaker if possible

- Cooling tower m/u lost resulting in higher silica in CW plating out on condenser tubes

17
Q

At what power level and how long do you have to perform BDAS check following a trip?

A
  • ≤2x10-6%

- Within 1 hour