40AO-9ZZ19 Control Room Fire Flashcards

1
Q

What are the RELIABLE instruments on the RSP?

A
  • PZR level (Y)
  • PZR press
  • Loop 2B Tc
  • Loop Th
  • SG 1 Level
  • SG 1 Press
  • SG 2 Level
  • SG 2 Press
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What makes the “reliable” instruments on the RSP reliable?

A
  • Isolators in their circuits to

- Prevents effect from CR fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

During 40AO-9ZZ19 Control Room Fire, what are the initial actions PRIOR to leaving the CR

A
  • Trip Rx
  • Initiate MSIS
  • Direct RO’s perform App. A/B
  • Direct personnel to report to RSP
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

During 40AO-9ZZ19 Control Room Fire, what is the CRS’s initial actions at the RSP?

A
  • ‘B’ ADV disconnect switches to local

- Determine status of PBB

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How is Pressure Control established in 40AO-9ZZ19 Control Room Fire?

A
  • Disable non-class htrs
  • ‘B’ class htr controlled from RSP or locally
  • ‘B’ aux spray from RSP
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When would you swap suction sources for AF pumps?

A
  • CST < 10’

- RMWT ≤ 33’ align to other unit CST

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How is AFA tripped from RSP per 40AO-9ZZ19 Control Room Fire?

A
  • Adjust speed to max
  • Speed control transfer switch to “Remote Shutdown”
  • Trip with manual HS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

During 40AO-9ZZ19 Control Room Fire, how is Seal Injection verified/ ensured?

A
  • CH B running
  • Injection vlvs fail open
  • CHB-255 CNTMT isolation is open
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the C/D rate for 40AO-9ZZ19 Control Room Fire, and why?

A
  • 20-25°F/hr

- only 1 CH pump for m/u

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

During 40AO-9ZZ19 Control Room Fire, when and for how long do you soak the Rx head?

A
  • 300-350°F

- 50 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

During 40AO-9ZZ19 Control Room Fire, what is the TCA for Initiating MSIS?

A
  • 90 seconds
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

During 40AO-9ZZ19 Control Room Fire, what is the TCA for placing ADV disconnects in local?

A
  • 5 minutes
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

During 40AO-9ZZ19 Control Room Fire, what is the TCA for disabling RCP brkrs

A
  • 10 minutes
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

During 40AO-9ZZ19 Control Room Fire, what is the TCA for Disabling A & E CH pumps?

A
  • 1 pump running - 44 minutes
  • 2 pump running - 22 minutes
  • 3 pump running - 14 minutes
How well did you know this?
1
Not at all
2
3
4
5
Perfectly