Decrease in Inventory TAA Flashcards

1
Q

For a LCLOCA what is the assumed failure and why?

A
  • LOOP

- has adverse impact on core re-flood

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

For a LBLOCA, what is the Design SI Flow Assumptions?

A
  • 75% flow from 2 HPSI (25% out the break)
  • 100% flow from 1 LPSI
  • 50% flow from 1 LPSI
  • 100% from 3 SITS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

For a SBLOCA what is the assumed failure?

A
  • LOOP & loss of 1 DG
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the design criteria for ECCS?

A
  • Max cladding temp - ≤ 2200°F
  • Oxidation of cladding - ≤ 17%
  • ≤ 1% of cladding reacts to produce H2
  • Maintain coolable geometry
  • Long-Term cooling
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

During a SBLOCA what is credited for the RCS Heat Removal Safety Function management?

A

SBLOCA

  • 2 phase natural circ
  • SI Flow
  • SG’s

LBLOCA

  • ECCS thru core and out break
  • SDC HX once on recirc (RAS)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When is an RCS cooldown performed following a LOCA?

A
  • 1 Hour
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

During a LOCA, what is the purpose of CS?

A
  • CTMT integrity
  • Prevents H2 gas pockets (mixes atm)
  • Scrubs Iodine from atm
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

For Decrease in Inventory TAA, what is the assumed failure for a LD line break outside of CTMT?

A

CHB-515 does NOT auto close on High RHX outlet temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How long do you have to isolate a LD leak outside of CTMT?

A
  • 10 minute TCA
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are the 5 phases of mass energy release during a LOCA?

A

Blowdown Phase - Initial leak, cladding cooled by leakage
Refill phase - Refilling core downcomer, not fuel cladding heats up
Re-flood phase - SITS refill core cladding begins cooling
Post Re-flood phase - Total core coverage with HPSI/LPSI
Long Term period - Restores CTMT press.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly