40AO-9ZZ17 Inadvertent PPS-ESFAS Actuations Flashcards
What are the entry criteria for Inadvertent PPS-ESFAS Actuation
- Actuation with equipment operation when setpoints not exceeded
- Cooldown in progress and you forget to reset PZR/SG variable setpoints
Describe ESFAS signal reset sequence
- Check Bistable trip lights (B05) not lit or in bypass (normally dark)
- Check Initiation relay lights (B05) are lit
- Check ARC signal lamps (top of PPS cabinets A/B) are lit
During an inadvertent PPS-ESFAS Actuation what is RX trip criteria
- Inadvertent CSAS and unable to restore cooling to RCP’s (10min w/ seal inj. 3min w/o)
- Inadvertent MSIS when >5% and any MSIV or FWIV closes
What are the mitigating actions for an inadvertent AFAS
- Override and control AFW FCV’s (prompt and prudent)
- If AFA <1000rpm for 5min trip it
- If SGBD isolated updated constants to 0
- Reset signal
- Restore support systems
What are the mitigating actions for inadvertent CIAS
- If LD isolated run 1 CH pump
- Reset CIAS
- Restore WC to CNTMT
- Restore Chillers
- Open CNTMT sump isolations
- Restore RU-1
What are the mitigating actions for an inadvertent MSIS
- Trip Rx if >5% and any MSIV/FWIV closes (trip prior to AOP entry)
- Use ADV if SG isolated
- If FW lost restore level with AF A or B
- Check condenser reheat tray level and override/restore trap isolations (1133/1134)
- Realign AS x-tie header
- Reset MSIS
- Restore affected systems
What are the mitigating actions for an inadvertent CSAS
- If CS running NOT for SDC stop it (anti-pump or SIAS override)
- Override and close CS header vlvs (wait until vlvs finish stroking)
- Restore NC to CNTMT (open RTN first b/c of reliefs)
- If unable to restore NC, Trip Rx, stop RCP’s isolate B/O (10 w/ seal inj, 3 min w/o)
- If IA isolated, check if LD or BD isolated, flag HS if needed then restore IA
- If LD lost run 1 CH pump
- Restore Seal B/O to VCT
- Reset CSAS
- Restore systems
- IF HPSI/LPSI ran >1hr on mini-flow notify engineering
What are the mitigating actions for an inadvertent SIAS/CIAS
- Override/stop HPSI
- Bleed off pressure downstream of LPSI injection vlvs (BEFORE STOPPING LPSI)
- Override/stop LPSI (3.0.3 if stopped before pressure bled off)
- Stop CS if not on SDC
- Reset PZR htrs
- If LD isolated run 1 CH pump
- Restore NHN-M71 (DC flow control)
- If SGBD isolated change constants to 0
- Override and start CEDM ACU’s
- Override/operate ECCS vlvs as needed for SDC
- Reset SIAS/CIAS
- Restore Systems
- IF HPSI/LPSI ran >1hr on mini-flow notify engineering
What are the mitigating actions for an inadvertent RAS
- Stop SI pumps if running
- If SDC lost due to LPSI trip
- LPSI SDHX bypass to 20%
- Close LPSI cold leg injection
- Open SDC loop warmup bypass
- Override restart LPSI
- Restore SDC flow
- Reset RAS
- Restore systems
How is an ESFAS initiation relay reset
Push reset button for EACH affected initiation relay
How is an ESFAS Aux relay trip reset
Press at least on reset push button
What is the minimum speed for AFA and how long can it run like that
- 1000 RPM
- 5 minutes
- Trip if exceeded
Can you restore LD before or after resetting an inadvertent CIAS
Can be restored BEFORE resetting
What is the concern if RU-1 and containment sumps are lost (inadvertent CIAS)
Requires entry into 3.0.3