Radon control measures:
Gas permeable layer of X
4” depth gravel beneath floor slabs
Radon control measures:
Soil gas retarder made of X
6 mil Visquene placed above gas permeable layer
Radon control measures:
The use of X to reduce entry
Use of Caulk to reduce entry through cracks
Radon control measures:
Venting of concealed spaces with X
3” to 4” PVCC pipe which may include power venting.
Radon control measures:
Doing what to masonry blocks
Capping off masonry block walls with solid materials.
Radon control measures:
Solid covers over X
Sump and well pits.
What is the safe and acceptable standard for radon?
None
Radon is the X leading cause of lung cancer
second
Natural outdoor radon gas level
0.4 PCI/L
Target level for indoor radon levels?
0.4 PCI/L same as outdoor
How many homes exceed target radon levels?
2/3
Average level in U.S home of radon?
1.25 PCI/L
What does PCI/L stand for?
Pico Curies per Liter
EPA take action level of radon
4 PCI/L