HCMT Train Electric Flashcards

You may prefer our related Brainscape-certified flashcards:
1
Q

Where are the Pantos located?

A

No 1 end all motor cars

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is used to raise the Pantos

A

Electrical and pneumatic process

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What pressure is needed to raise the pantoss

A

700 kpa

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

If MR pressure is not sufficient and panto raise button is pressed what happens

A

110v DC powers the auxiliary compressor to raise the local panto.
Once MR reaches 400-450 pantos on the Mp will raise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where is the high voltage box located and name the 2 things inside

A

No 1 end all motor cars
HSCB
Harmonic wave detection device

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What button is used the reset the HSCB is prompted

A

TCU/ACU rest button

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What does the harmonic wave detection device do and can it be reset

A

Safeguards against power quality problems
Yes, TCU/ACU reset button

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The electrical auxiliaries system converts 1500 vDC to what

A

3 phase 415 vAC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What 4 equipment runs on 415 vAC

A

Battery chargers
Air compressor
Traction Cooling system
HVAC - cab and saloon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The battery charger converts 415 vAC to what

A

110 vDC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is in the variable voltage variable frequency cabinet and what does it convert 1500 vDC to?

A

Traction inverter
3 phase variable voltage and variable frequency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where is the auxiliary power supply located and what 4 things is inside

A

Tc and DT cars
Auxiliary inverter
Medium voltage box
Battery box
Battery charger

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The battery box supply what voltage and for how long

A

110 v DC
2h in emergency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The battery charger converts 3 phase 415 vDC to what

A

110 vDC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What runs on 240v AC

A

GPOs cab and saloon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

In emergency conditions what 3 things will have a reduced function

A

Saloon lights will reduce to 50%
HVAC: fresh air fan operates with 110v DC battery power for 2 h
Saloon doors operate as normal

17
Q

What happens with the HVAC when in train wash mode

A

Closes the fresh air damper and close fresh air fan

18
Q

When power is lost what 3 things will the saloon HVACs do automatically

A

Open the fresh air dampers fully
Close the return air dampers
Fresh air fan operates on 110v DC for 2h

19
Q

What happens when internal smoke detection happens

A

Internal smoke detectors relay signal to 2 HVAC
TMS display level 2 alert to driver and 15 sec timer starts
15 sec eTIS escalate to level 1 and initiate smoke mode
Upon internal smoke signal the HVAC shuts down and opens fresh air dampers
Internal fire doors close

20
Q

What happens in the event of external smoke detection

A

2 external smoke detectors detected smoke, signal is sent to every HVAC to close fresh air dampers after 15 sec
Driver is alerted via eTIS
HVAC will automatically open fresh air damper once no smoke is detected
If the fresh air damper is closed for 10mins it will automatically open to allow fresh air

21
Q

Name the 4 circuit breakers that will cause the train to fail

A

Cab activation
Traction control
Emergency brake loop power supply
Brake control supply

22
Q

The emergency brakes will apply when:
(9 answers)

A

MC to Emy
Hand and foot pilot not set
EMS button
Trip activated
Vigilance penalty application
MR below 600 kpa
Towing unit demand for Emy brake
Safety system bypass reminder timeout
Physical interruption of the safety loop

23
Q

The safety loop cannot be reset until

A

Stationary for 3 sec
Reason for Emy brake is reset
MC to max brake and reverse to neutral