Caulfield Group- Sandringham Flashcards
What is the speed between Down end Federation Sq to Richmond?
65
What is the speed between Richmond to Sandringham
70
What is the speed on the Caufield Loop
60
What is the speed at Sandringham plat ( dead end)
25
What are the safeworking systems on the Sandringham line
ABS
Name the 3 terminating locations on the Sandringham line
Elsternwick
Brighton Beach
Sandringham
Egg bacon sandwich
Name the 2 stabling locations in the Sandringham line
Brighton Beach
Sandringham
Bacon sandwich
Who is the controlling singallers at Elsternwick and recorded or not
Elsternwick Signal Box and passage of trains with an Annett Key
Not recorded
Do you use high beams on Sandringham line
No
If the Annett Key is removed what will the signal aspect be
Stop position
With illuminated letter “A” extinguished
At Elsternwick how will the caution order be given
Handed
If detained at stop and illuminated letter “A” is extinguished, who do call
Caulfield Signal Control Panel
Elsternwick:
On the down what is the station limits
B313
B341
Elsternwick:
On the up what is the station limits
B330
B306
Who the is controlling singaller at Brighton Beach and recorded or not
Brighton Beach
Not recorded
How can you receive your caution orders at Brighton Beach
Handed
Do you do the points on the Brighton Beach
No
How many sidings at Brighton Beach, letter or nr
2 sidings
Letter (A+B)
At Brighton Beach do the sidings have a shared or individual dwaft
Shared dwarf
How do you get access to the up line at Brighton Beach
Rostered trains will run to Sandringham and depart on the up for access to Brighton Beach walking path
Who is the controlling signaller at Sandringham and recorded or not
Sandringham
Not recorded
Do you receive the caution order at Sandringham
Handed
Do you do the point at Sandringham
No
How many siding tracks at Sandringham and letter or nr
4 tracks including plat
Nr
What sidings at Sandringham share a dwarf
3 &4
What operating instructions for prepping a train on siding 2
Met bus risk on plat side
At Sandringham do siding 1 and 2 share a dwarf
No, individual
What do you do if the home signal at the down end of Elsternwick platform 2 is at stop with NO illuminated letter A?
- Contact Area Controller (Caulfield Signal Control Panel)
- They will check if the Annett key has been removed. If it is not removed, they will advise as failure of illuminated letter A
- Check the points are set
- AC will give you Verbal permission to pass the signal as per rule 1 section 3.
(NB: same procedure at Footscray Annett key points, platform 6)