Safety Injection (SI) Flashcards

1
Q

State the minimum flow required for operation, min. flow for continuous operation, shutoff head, and rumble region of the Safety Injection Pumps

A

HPSI: 85, 225, 1776-1962
LPSI: 100, 2400, 210#, 2500-3500
CS: 150, 2100, 290#, 1800-2800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Describe the SDC Train A/B Low Flow alarm

A

alarm is tied to breaker, if pump trips, no audible?

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

State the SI design criteria

A

CLOTH

Coolable Geometry
Long term cooling
oxidation less than 17%
temperature of the cladding less than 2200F
hydrogen production less than 1%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

State the Containment Spray design criteria

A

reduce peak Containment pressure 50% within 24 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Does CHA-HV-532 RWT to Train A SI Pumps Suction reposition on a RAS?

A

No, manual action required.
SIA-UV-664 Ctmt Spray Pump A Recirc Valve will close

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the purpose of the Trisodium Phosphate baskets?

A

raise pH (greater than 7.0) to ensure iodine stays in solution

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which RCS loops do HPSI’s feed?

A

HPSI flow goes to one hot leg and all four cold legs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Is Shutdown cooling warmup line flow read by the LPSI loop flow transmitters?

A

Yes, however, the flow does not go to the RCS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the open permissive for the SDC Suction valves (651-656)?

A
  • Open permissive: ≤ 385 psia RCS pressure
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the close permissive for the SIT outlet valve?

A
  • Outlet MOVs
    o Auto open: SIAS OR PZR press > 410 psia
    o Close permissive: PZR press ≤ 405 psia and no SIAS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the minimum flow that can be read for a HPSI?

A

All Foxboro flow indicators go off-scale at approximately 8 to 10% due to limitations with
the square root extractors. The HPSI flow indicators, for example, will not read accurately below 75 gpm.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly