State the minimum flow required for operation, min. flow for continuous operation, shutoff head, and rumble region of the Safety Injection Pumps
HPSI: 85, 225, 1776-1962
LPSI: 100, 2400, 210#, 2500-3500
CS: 150, 2100, 290#, 1800-2800
Describe the SDC Train A/B Low Flow alarm
alarm is tied to breaker, if pump trips, no audible?
State the SI design criteria
CLOTH
Coolable Geometry
Long term cooling
oxidation less than 17%
temperature of the cladding less than 2200F
hydrogen production less than 1%
State the Containment Spray design criteria
reduce peak Containment pressure 50% within 24 hours
Does CHA-HV-532 RWT to Train A SI Pumps Suction reposition on a RAS?
No, manual action required.
SIA-UV-664 Ctmt Spray Pump A Recirc Valve will close
What is the purpose of the Trisodium Phosphate baskets?
raise pH (greater than 7.0) to ensure iodine stays in solution
Which RCS loops do HPSI’s feed?
HPSI flow goes to one hot leg and all four cold legs
Is Shutdown cooling warmup line flow read by the LPSI loop flow transmitters?
Yes, however, the flow does not go to the RCS
What is the open permissive for the SDC Suction valves (651-656)?
- Open permissive: ≤ 385 psia RCS pressure
What is the close permissive for the SIT outlet valve?
- Outlet MOVs
o Auto open: SIAS OR PZR press > 410 psia
o Close permissive: PZR press ≤ 405 psia and no SIAS
What is the minimum flow that can be read for a HPSI?
All Foxboro flow indicators go off-scale at approximately 8 to 10% due to limitations with
the square root extractors. The HPSI flow indicators, for example, will not read accurately below 75 gpm.