Containment Purge (CP) Flashcards

1
Q

The Containment Purge system is used to maintain nitrogen cover gas on the steam generators during wet layup conditions.

True of False?

A

True

The GA System uses a regulator to releases nitrogen into the CP System during the time that a cover gas is being maintained within the Steam Generators.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the pressure band for Containment pressure per Tech Spec 3.6.4, Containment Pressure?

A

3.6.4 Containment Pressure

LCO 3.6.4 Containment pressure shall be > -0.3 psig and < +2.5 psig.
APPLICABILITY: MODES 1, 2, 3, and 4.
ACTIONS - COND ITION REQUIRED ACTION COMPLETION TIME 1 hour
A. Containment pressure not within limits.
A.1 Restore containment pressure to within limits.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the power supply for the Refueling Purge Containment Isolation Valves?

A

Refueling Purge CIVs (4)
* 42” ducting
* 2 supply / 2 exhaust duct CIVs (motor operated)
* Power: PHA/PHB
* Modes 1-4:
o Closed / de-energized / isolated with blind flange
o Not qualified for auto closure under DBA conditions. (LCO 3.6.3 bases)
* Auto isolates (CIAS or CPIAS)
o Signals can be overridden

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the cooling source for the Refueling Purge Normal AHU’s?

A

Refueling Purge Normal AHU (2)
* Oil impingement air cleaner, cooling coils, heating elements, and 2 (50% capacity) fans
* Cooled by Normal Chilled water (WC)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the primary concern with ventilation changes if PCN-V118 is open?

A
  • If transfer valve (CTMT to SFP) is open, water level changes could occur during ventilation changes.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What has a higher capacity Refueling Purge Normal Suppy or Exhaust Fans?

A

Refueling Purge Normal Exhaust Fans (2)
* Higher capacity than supply fans
* Maintains CTMT at a negative pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the Open interlock for Power Access Purge Supply Containment Isolation Valves (4A/5A)?

A
  • PKA/PKB
  • Fail closed
  • Operated in pairs from 2 MCR HSs
  • Normally energized and closed
  • Air is normally isolated to outside CIVs (4A/5B)
  • Auto isolate (CIAS or CPIAS)
    o Isolate < 12 seconds (3.6.3 bases)
    o Signals can be overridden
  • Inlet CIVs (4A/5A)
    Open interlock
    CTMT pressure < 0.03 psig (1” H2O)

     (PT-492A/493B)
    o Prevents damage to supply fan duct due to high pressure.