EMRG Start (FTD 2) Flashcards
What are the engine start ITT limits?
860-910 for 20 sec
910-1000 for 5 sec
If engine start ITT limits are broken, what are you actions?
Complete actions IAW Hot Start:
- PCL - Fuel Off
- Complete the Manual Dry Run if the PMS has failed to do so:
If so, get out the checklist and open Engine Dry Run (located in the normal procedures: N-23)
What are the limits for Engine Dry Run?
After an engine dry run allow the starter to cool for one minute before attempting restart. If the start has been attempted 3 times a 30 minute wait is required.
If ITT does not rise or stabilises below 54% on start up, what are your actions?
- PCL - Fuel off
Get out checklist and read the following Pg: N-23
- Starter - AUTO
- Igniters - AUTO
- Fuel Pumps - AUTO
- Engine Dry Run (on the same page)
If the starter remains on while the engine is running on the ground:
Get out the checklists and find the relevant checklist (located in the EMRG section), complete:
- Starter - Auto
If caution remains
- PCL - Fuel Off
- Batt 1 - Off