TB 149 - Residential Sprinkler Systems Flashcards

1
Q

As of January 1, _____, the State of California is requiring the installation of residential fire sprinklers in all new one and two family dwellings and manufactured homes

A

2011

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

California sprinkler law uses the NFPA ___D standard

A

13

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Residential Sprinkler System:
California sprinkler law includes new construction of garages, patios extending __’ from house and unattached structures greater than ____ sq. ft

A

4
200

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Sprinklers are only required in _______ areas of homes; attics or other combustible sealed spaces are exempt

A

Livable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Nationwide statistics show that most fires, injuries and deaths occur at home. The International Association of Fire Chiefs (IAFC) report that approximately _______ civilians perish annually from fire, with nearly ____ of those deaths occurring at home

A

3000
2/3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Residential fire sprinkler systems are primarily “life safety” systems with the purpose of preventing __________ and improving chances of occupant escape

A

Flashover

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Residential Sprinkler System:
According to the National Institute of Standards and Technology (NIST), a home fire can reach deadly proportions in as little as __ minutes , with __ to ___ minutes passing before first responders arrive

A

3
7 to 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Residential Sprinkler System:
Head temperatures range from ____ to ____ degrees

A

135 to 175

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Residential Sprinkler System:
Home fire sprinklers cover a minimum area of ___’x ___’

A

12’x12’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Home fire sprinklers Extended coverage heads can cover a ___’x ___’ area

A

20’x 20’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Residential Sprinkler System:
LADBS requires a (minimum) water demand capable of flowing __ heads for a period of ___ minutes

A

2
10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Residential sprinkler systems in Los Angeles are usually wet systems and don’t require the use of _____-______ solutions due to our mild climate

A

anti-freeze

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Chlorinated polyvinylchloride (CPVC) being installed. A solvent cement is used for connecting the joints. Note the ________ color of the CPVC pipe.

A

Orange

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

These include black pipe, copper pipe, chlorinated polyvinylchloride (CPVC), polybutylene (PB), schedule ___ steel or thin walled steel

A

40

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Identification signs are _________ by LADBS but the minimum size of sign and lettering is not regulated

A

Required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Sometimes cover plates or the sprinkler heads themselves are ________ over which can hamper the activation of the heads

A

Painted

17
Q

_________ heads are more heat sensitive than traditional heads

A

Pendant

18
Q

Residential Sprinkler System:
Pendent type residential sprinkler designed to activate between ____ – ____ degrees

A

135 - 175

19
Q

Pendent type residential sprinkler typically cover a ___ft. x ___ft. area

A

12ft. x 12ft

20
Q

Special extended coverage sprinklers can cover up a ___ft. x ___ft. area

A

20ft. x 20ft