Onan Generator Flashcards

1
Q

Onan Generator:
Onan used to power the ___-volt:
______
______
______

A

110
Lighting
Electrical Outlets
Battery Charger on the Apparatus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Onan Mobile Genset Geerator Mode#
75HDKAL-1___ (95’-03’ LTI)

A

C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Onan Mobile Genset Geerator Mode#
75HDKAL-1___ (06’-09 LTI)

A

E

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Onan Mobile Genset Geerator Mode#
75HDKAL-1___ (16’ Pierce) AKA Cummins Onan

A

B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Onan Generator: AC volts ___/___

A

120/240

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Onan Generator: KVA ___ kW ___

A

7.5
7.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Onan Generator: amps ___

A

31

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Onan Generator: Hz ___

A

60

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Onan Generator: RPM ____

A

1800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Onan Generator: LTI & Pierce controls are located in ____ locations

A

3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Generator Controls: (6)
________
________
________
________
________
________

A

Start/stop
Temperature gauge
Oil pressure
Pre-heat switch
Volts gauge
Hour meter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

LTI left compartment controls
-start/stop
-pre-heat switch
-________________
-________________
-________________

A

Circuit breaker panel (2 main breakers)
Quartz light switch
Cord reel rewind speed control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Onan: tractor cab controls
- Start/stop
- __________
- __________

A

Pre-heat switch
Indicator light

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

DC control breaker:
Circuit breaker that protects the ___ Volt components of the generator

A

12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

AC volts gauge indicates the voltage that the generator is putting ______

A

Out

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Hertz meter measures frequency ______ in hertz

A

Output

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Cab quartz light is controlled by (3) places
1. __________
2. __________
3. __________

A
  1. Left cab compartment
  2. Cab dashboard
  3. Light assembly
18
Q

Cord reel 00’-09’ is a ______ feet reel

A

200

19
Q

Cord reel 00’-02’ is a ______ feet reel

A

200

20
Q

Electric cord reel outlet box contains two ___ -amp receptacles, each on their own circuit

A

20

21
Q

Genset when operating supplies power to the ______ panel

A

Electrical

22
Q

Electrical panel located in the ___ compartment of the tractor chassis with ___ circuit breakers

A

Left
12

23
Q

Genset can power (5)
1. ________
2. ________
3. ________
4. ________
5. ________

A

Air cushion fans
Submersible pump
Water vacuum
Lights
Other appliances

24
Q

Keep a no-load operations to a minimum. ALWAYS have some loads ________ when running long periods

A

Connected

25
Q

2016 pierce preheat limits longer than ___ seconds can damage the glow plug

A

20

26
Q

16’ Pierce: hold control switch in PREHEAT position in accordance to the temperature;
- ___ seconds - above ___°F (___°C)

A

10
50°
10°

27
Q

16’ Pierce: hold control switch in PREHEAT position in accordance to the temperature;
- ___ seconds - ___F to ___°F (-___°C to ___°C)

A

15
0° to 50°
-17° to 10°

28
Q

16’ Pierce: hold control switch in PREHEAT position in accordance to the temperature;
- ___ seconds - below ___°F (___°C)

A

20

-17°

29
Q

Onan Generator:
Cranking Engine: do not crank engine for more than ___ seconds at a time

A

15

30
Q

Onan Generator:
Cranking Engine: wait ___ minutes before attempting to the start again

A

2

31
Q

Starting the Onan generator: when stopping, let it cool down by running at no-load for ______ to ______ minutes then pus the stop button.

A

Three to five

32
Q

Generator logic control (GLC) is designed to auto ______ or ______ in ___ settings

A

Start Stop 6

33
Q

Generator logic control (GLC) will start when batteries are below ___ Volts and will run until the battery voltage has exceeded ___ volts for one hour

A

12.1 13.3

34
Q

Generator logic control (GLC) to enter auto mode, press the button marked “______”, the indicator light on the button will light.

A

AUTO

35
Q

Generator logic control (GLC) when running, the ______ bolt symbol will illuminate

A

Lightning

36
Q

Generator logic control (GLC) to turn auto mode off, press the ______ mode button

A

Auto

37
Q

Generator logic control (GLC) setting time: to set time of the day, stop time or start time, press & hold the corresponding button for ___ seconds until the hour digit flashes.

A

3

38
Q

When starting the generator, the generator logic control will crank the generator for ___ seconds, if it has not started, it will stop for ___ seconds, after the ______ attempt the generator does not start “GEN FAIL”

A

5
5
Fifth

39
Q

Display
- Time of day
- Battery voltage
- Generator run time

A

.

40
Q

Onan Generator:
2016 pierce run at approximately ___ rated power for one hour weekly

A

1/2

41
Q

2016 pierce change oil after the first ___ hours of operations

A

50

42
Q

The Onan is powered by a _________ engine

A

Diesel