LTI Aerial Ladder QS100 Flashcards

1
Q

QS-100 Aerial Ladder: ___ sections of all rectangular tubular steel

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

QS-100 Aerial Ladder: ____ pound load tip

A

250

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

QS-100 Aerial Ladder: ______ & ______ extension

A

Hydraulic & Cable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

QS-100 Aerial Ladder: ___” handrails

A

15”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

QS-100 Aerial Ladder: K-braced rungs spaced ___” on center ___” diameter

A

14”
1 1/2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

QS-100 Aerial Ladder: retracted lengths is ___

A

31.8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

QS-100 Aerial Ladder: extended length is ___’

A

94

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

QS-100 Aerial Ladder: elevated height of the aerial is ___’

A

100’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

QS-100 Aerial Ladder: elevated ranges from -___° to +___°

A

-4° to +75°

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

QS-100 Aerial Ladder: ____, directly driven off of the chassis trans, powers a ______ pump

A

PTO
Hydraulic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Hydraulic Pump: ______ piston

A

Axial

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Hydraulic Pump: _______ displacement type pump

A

Variable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Hydraulic Pump: capacity of ___ GPM

A

20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Hydraulic Pump: ___ gallon steel reservoir it’s baffles & magnetic drain plug.

A

40

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Aerial Ladder Hydraulic Cylinders: ______ & ______ cylinders

A

Hoist
Extension

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Aerial Swing (Rotation): antifrication bal bearing & ring gear attach the aerial to the chassis; thus providing ___° continuous rotation

A

360°

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Aerial Swing (Rotation): rotation is achieved through a _______ gear reduction drive powered by a hydraulic motor.

A

Planetary

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Aerial Swing (Rotation): an ________ disc-type brake is used to stop the rotation of the aerial turn table.

A

Automatic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Apparatus Level Indicator: ______ indicates full operating capacity

A

Green

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Apparatus Level Indicator: ______ indicates 50% operating capacity ___ to ___° degrees

A

Yellow
3.5° to 8.0°

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Apparatus Level Indicator: ______ indicates aerial ops prohibited

A

Red

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Inclinometer: ______ filled gauge mounted to the main section of the aerial

A

Liquid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Apparatus Level Indicator: A floating ball-type angle indicator calibrated from -___° to +___°

A

-20° to +80°

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

PTO Power Take Off: Mounted on the ________

A

Transmission

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
PTO Power Take Off: Trans fluid goes to the ____ when the PTO switch is turned on.
PTO
26
PTO Power Take Off: A ______ within the PTO engages the shaft that transfers power to the hydraulic pump
Clutch
27
PTO Power Take Off: The ______ supplies and drives the PTO to drive the main hydraulic pump
Engine
28
LTI QS100: Variable Displacement Pump: Create _____ PSI at approximately __ GPM
2800 20
29
Variable Displacement Pump: With the pump operating & all controls are in neutral, the oil merely ________ within the pump cavity under negligible PSI
Circulates
30
Aural Main Control Valve: Opens to let ________ fluid to the aerial control ______ valves
Hydraulic Spool
31
Aural Main Control Valve: Opens when the ______-____ is depressed or the emergency blocking ______ is actuated.
Dead-Man Solenoid
32
Aural Main Control Valve: Three other Aerial Spool Valves are mechanically linked to the aerial control levers 1. ________ 2. ________ 3. ________
Hoist Rotation Motor Extension Cylinders
33
Aerial Electrical System: The aerial electrical system is a ______ wire; negative ground return type, utilizing the apparatus ______ as ground
Single Frame
34
Aerial Electrical System: Power from the tractors system is transferred to the aerial through the electrical swivel ______.
Coupling
35
Aerial Power Switch when turned on provides primary aerial systems and accessories with _______ power.
Electrical
36
PTO Switch & Indicator Light: Electric switch that energizes a _______, which allows transmission fluid to the ____
Solenoid PTO
37
PTO Switch & Indicator Light: Switch will not energize unless trans is in __ and _____ ______ set
Neutral Parking Break
38
EPU: ______ loaded at each outrigger control box & activates the emergency power unit during ________ or ________ failure
Spring Electrical or Hydraulic
39
Communication System: ___-way comm between personnel at tip & aerial pedestal.
Two
40
Communication System: Control unit installed at the aerial pedestal console - ______ - ______ - ______
Listen Volume Push to Talk Talk Volume
41
Communication System: “________” hands free speaker at the tip of ladder fly section
Talkback
42
Rotation Limiting System: Will not allow the aerial/turntable to be _______ into an area which is not supported by fully deployed outriggers unless ________ switch is engaged
Rotated Override
43
Safety & Capabilities: Position the ladder approximately ___ to ___ inches above objective
6 to 12
44
Safety & Capabilities: Personnel on ladder shal maintain a distance of ___ FT apart
10
45
Outrigger Safety: when using the jack pads under icy or slippery conditions, “______ ____” the surface before placing pad under outrigger
Rough Up
46
Outrigger Safety: NEVER set outrigger jack over a ______ drain or ________ cover
Storm Manhole
47
Outrigger Safety: ______ ______ use every time the outriggers are deployed
Jack Pads
48
Outrigger Safety: NEVER operate aerial on a _________ outrigger side
Short-Jack
49
Reverse Loading: never ________ the aerial, the aerial is designed with its max strength available in the unsupported configuration.
Support
50
Always keep aerial at least ___ feet away from all wiring.
10
51
LTI QS100: Do not operate with ladder elevated in wind exceeding ___ MPH
30
52
Water Streams - Ladderpipe: capacities are established with outriggers fully extended and set, turntable level within ___%/___° and aerial unsupported
6%/3.5°
53
Full rated capacities up to but not including ___% - ___°
6% - 3.5°
54
___% reduced on grades between ___% & ___% - ___° & ___°
50% 6% & 14% 3.5° & 8.0°
55
Aerial Loading Warning Display Alarm activates when the max aerial load is exceeded by ____ - ____ lbs.
50-100
56
-2° - 9° Base ___ I-Mid ___ O-Mid ___ Fly ___
0 0 0 250
57
-10° - 29° Base ___ I-Mid ___ O-Mid ___ Fly ___
250 0 0 250
58
-30° - 39° Base ___ I-Mid ___ O-Mid ___ Fly ___
250 250 0 250
59
-40° - 59° Base ___ I-Mid ___ O-Mid ___ Fly ___
250 250 250 250
60
-60° - 64° Base ___ I-Mid ___ O-Mid ___ Fly ___
500 250 250 250
61
-65° - 75° Base ___ I-Mid ___ O-Mid ___ Fly ___
500 500 250 250
62
Anything greater than ____° 500lbs & water.
46°
63
Between ___° to ___° & ___’ to ___’ you can have ___ LBS & ____ tower
46° to 26° 65’ to 85’ 250 Water
64
Anything greater than ___° & ___’ either 250 or water
26° & 85’
65
Outrigger System: ___’ spread 93’-01’ & ___’ spread 01’-09’
16’ 14’
66
The preset fast idle at pedestal and outrigger control box is ____ to ____ RPM
1500 to 1600
67
Fully deployed indicator lights will light at ____ lbs
800
68
Extend down low side jack until bubble in the aerial leveling indicator moves past level ___”
1/8”
69
Chose hole that is a min ___” below jack skirt. Fully insert manual locking pin & then back out ___” if leveling is not required.
1/4” 1/2”
70
Aerial Extension Indicators are marked off in ___’ increments
5’
71
Both rotational directions are allowed but swinging toward the short-jacked side will be cut out after approximately ___° of rotation
72
Hydraulic system pressure gauge registers working PSI in hydraulic system from ___ to ____.
0 to 5000
73
Rotation interlock override ___ to ___ will allow the ladder to move into restricted positions.
06’ to 09’
74
Over ______ offords the most stable aerial operating position.
Rear
75
EPU is a __ V dc electric motor & ___ GPM at ____ psi pump
12 1.5 2000
76
EPU 06’-09’ is rated for a max of ___ minutes continuous operation. Used over long period at a ___% duty cycle which is approximately ___ minutes in every ___ min (2.3 min on and ___ min off)
7 23% 2.3 10 7.7
77
96’-03 rated max is ___ min & used over a long period of time at a ___% duty cycle, which is approx. ___ seconds in every ___ min.
3 7 21 5
78
Anchor attachment point ____’ located on both left and right sides has a rating of ____ lbs
2009’ 9000
79
Capstan Receiver 09’ has the same ___ lbs rating as the tip load of the aerial Ladd.
250
80
Using the winch lifting system wrap the rope ___ to ___ times around the drum starting at the bottom working it up until it reaches the winch’s upper arm
4 to 5
81
Blocking solenoid Located Just ______ of the Pedestal Below the Base of the Main Section
Left