There are approximately _______ fumigations in Los Angeles County each year
32,000
As hydrogen cyanide was phased out, ________ ________ replaced it as the fumigant of choice in applications previously calling for hydrogen cyanide
Methyl Bromide
As methyl bromide was phased out, it was replaced by ________ ________ which is currently used in over ___% of all fumigations throughout the United States
sulfuryl fluoride
95
Although sulfuryl fluoride is only about ____ to ____ as effective as methyl bromide, it is a safer fumigant
1/3 to 1/2
However, skin contact with liquid sulfuryl fluoride could cause frostbite because the temperature of the fumigant will be approximately -___° Fahrenheit (boiling point) as it changes from a liquid to a gas
67
sulfuryl fluoride which is marketed under four different brand names:
- ________
- MasterFume
- Profume
- Zythor
- Vikane
Chloropicrin is a _____ gas with an extremely strong ______ which is used as a warning agent.
Tear
Odor
Chloropicrin becomes unstable at temperatures above ____°F, and can decompose violently above this temperature
140°
Vapors are ___ times heavier than air and are non-skin absorptive as a gas
5.7
Aluminum Phosphide - cannot be used inside structures nor closer than ____ feet from a structure where humans and/or domestic animals reside
100
Aluminum Phosphide - The gas is colorless with a garlic-like odor, vapor density of ____ (slightly heavier than air)
1.18
incidents involving aluminum phosphides:
• Request a full _______ assignment
• do not use water
HazMat
Methyl bromide is colorless, odorless and has a boiling point of ____° F
38.5
Methyl bromide - It’s heavier than air with a vapor density of ____
3.27
The flammable range is from ___% to ___% in air, which correlates to a “1” on the NFPA 704 Placard for flammability
10 to 16