Siemens Pneumatics & Cab Equipment COMMS systems Flashcards

1
Q

Holding brake pressure

A

110 kPa

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

B1 - B6 pressures

A

B1 - 57 kPa
B3 - B5 + 27 each step
B6 - 189 kPa

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Emergency cylinder pressure

A

280 kPa

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

If a deadman’s switch (hand/ foot switches) is not set while train is above 0.2km/h what will happen? *

A

A tone will sound for 3 seconds and then EMERGENCY BRAKE APPLIES

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Why are they called hand and foot switches and not pilot valves? *

A

Because they are operated electrically not pneumatically

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How do we set hand switch?

A

Move 15* anti clockwise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is VICERS comprised of?
2 sub units

A

Vigilance control system
Event recording system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the Vigilance Control System comprised of? (5)

A

• Task linking of driver controls (MC, whistle)
• VICERS acknowledgement button
• Buzzer
• Vicers Fault Indicator
• Vigilance Activation Valve/ Relay

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What will reset the Vicers timer?

A

Operation of the
• MC
• whistle
• Vigilance button when it flashes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What warning will a driver get that vicers cycle has advanced towards EMY brake?

A

Vicers light flas for 5 secs
Audible buzzer for a further 5 seconds

If not pressed EMY brake applies

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What will happen if VICERS ACKNOWLEDGEMENT BUTTON is held down for more than 5 seconds?

A

Emergency brake will apply

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How will we know when to isolate Vicers?

A

A vicers fault light illuminates on the fault panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

If pantos are lowered does that shut down the train?

A

No we must press the stable button otherwise the batteries will go flat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Does the CCTV automatically turn on when cab is activated?

A

No you press the S button

Unless a DDA is pressed or a PEI is activated/ acknowledged

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What does the wheel slip status light indicate?

A

Yellow illuminated indicator when wheel slip is detected

EP and sanders will operate (ED may
be removed)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When does overspeed indicator illuminate? *

A

When train exceeds 119 km/ h

17
Q

When TDN is entered on DDU does driver need to also input into TDN to DTRS ?

A

No it transfers automatically

18
Q

What indicates a DDA has been pressed?

A

DDA flashes WHITE 5 times and then remains steady

On pressing button CCTV will turn on

19
Q

Cab to cab indicator?

A

Flashes yellow until acknowledged

20
Q

PEI indicated how?*

A

Emergency Intercom button flashes Red
Tone emitted
CCTV activated once button acknowledged
Mic used to communicate with paxs

21
Q

What button to communicate with passengers?

A

Cab to saloon
Yellow when on
Use mic to talk

22
Q

Blue light flashing door close light can we get traction?

A

No

23
Q

When can yellow door release buttons not operate?

A

When train is above 0.2 km/h

24
Q

Cab speaker is activated when?

A

The switch is illuminated white

Default position is isolate on older trains
Need to unisolate to hear others speak

25
Q

When a PEI call is made when / how does cab speaker turn on?

A

Automatically

26
Q

What is EI (EMERGENCY INTERCOM) used for?

A

To respond to PEI CALLS

27
Q

When will CCTV come up on a PEI call?

A

When PEI button is activated

28
Q

What must be used to communicate with the passenger on a PEI call?

A

The microphone on the switch panel

29
Q

To what equipment does BCU send electronic signals ?

A

To & from TCU for ED SERVICE braking

To brake Modules for EP

….Info is processed and adjusted (weight, speed of train etc) via pressure limiting valve.
Then pressure goes to relay valve which allows corresponding AUX res air to enter brake cylinders

30
Q

When will EP take over during wheel slide on a DM car?

A

When braking effort falls below 90% of braking request

31
Q

How can ED be reset if lost during wheel slip?

A

MC into zero or any powering position
for

1sec +

32
Q

What does the Sanding Control unit operate in conjunction with?

A

BCU
& Wheel slip unit

33
Q

Shen does a red LED illuminate on the sand boxes?

A

When sand level is below 20%

34
Q

When do the sand heaters turn on?

A

When the temperature falls below 5’ Celsius

35
Q

When are sanders non operational?

A

Below 5km/h

36
Q

Do the sanders operate during ED braking or powering?

A

No

37
Q

What will happen with Brake Cylinder pressure when MC is moved to B1, B2 or B3 if train is on a gradient?

A

It can roll as Brake Cylinder pressure will fall below Holding Pressure