When should an apparatus with a fully qualified RIT be dispatched?
any known structure fire
When should RIT be established?
- ASAP
- when personnel are working in a hot zone
- whenever IC deems it necessary
When may a RIT not be req’d?
defensive fire
When can IC use discretion to terminate RIT(?)
fire is fought offensively and is under control
How many trained members that have passed a BFES approved RIT course make up qualified RIT?
3
When may more than one RIT be req’d?
RIT is not req’d for every sector making entry into hot zone, but more than one may be req’d if resources are available depending on size and layout of incident
What shall RIT Captain announce when they arrive on scene?
Ex. S201 on- scene- RIT
What are Level 1 RiT actions? (7)
- gather info
- complete a RIT worksheet
- stage equipment
- discuss situation w/ IC, ECP and ISO
- familiarize themselves with structure layout
- perform 360 layout
- locate secondary means of egress
Where may RIT be staged at a high-rise incident?
located inside building in forward staging area
What is equipment for Level 1 RIT? (9)
- PPE and SCBA
- RIT kit
- Tag line
- Flashlights
- TIC
- Forcible entry tools
- cutters
- straps
- ladders
When is Level 2 RIT implemented?
- if scene escalates
- 2nd alarm is called
- when requested by IC
What are Level 2 RIT actions? (4)
- gather info
- secure power supply
- prepare lighting
- ensure multiple means of egress (ladder windows, roofs, remove obstacles- bars, chains, locks)
What must Level 2 actions be aware of?
adverse reactions of making rescue openings. RIT should consult with IC and ventilation crews before acting.
What equipment is included in Level 2 RIT?
- Level 1 RIT equipment
- Lights
- forcible entry tools (K23, bullet saw)
- cribbing and shoring equipment
- heavy hydraulics/ air bags
- additional ladders
What actions constitute Level 3 RIT?
RIT beginning rescue operations