Taxpayers also 38/68 build code Flashcards

1
Q

A force PERPENDICULAR to supporting member, EVENLY APPLIED to bearing structure?

A

Axial Load

PS eccentric does not pass through the center and load NOT EVENLY applied

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A course of brick built out from the face of a wall, as steps in reverse?

A

Corbelling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Loads exerted outwardly on a horizontal plane?(walls usually not designed for this?

A

Lateral load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the dimensions of Gypsum Plank?

A
2" thick
2' wide
8' long
supported at 4' intervals or
7' if heavy gauge steel edged plate used
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When masonry surfaces lose layers of mass, exposed to heat?

A

Spall

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Tax, What class do they fall under?

A

Class 3
exterior firewalls
interior wood

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Tax, What is the most common size?

A

Approx 100x100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Tax, What are the years they are divided into?

A
1900-1920 remove decorative cornice
usually 1 story some 2 story
1920-1960  most prevalent, usually 2 story,
 remove decorative cornice usually no
1960-present
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which tax is most prevalent?

A

20’s-60’s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Tax, 1920’s are usually how many stories?

A

Usually 1 some are 2

Would be considered wood frame building with exterior masonry walls, tin ceilings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Tax, What years building would u be able to remove decorative cornice?

A

1900-1920’s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Tax, 20-60’s are how big?

A

many are 2 stories- 1 tenant occupancy/ various stores on 1st fl.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Tax, 20-60’s Are there fire walls?

A

MAY HAVE

Variable termination points

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Tax, 20-60’s does removing cornice provide access to cockloft?

A

In most cases no.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Tax, 60’s-present What major difference would be in in this type of construction?

A

Steel Bar Joists replaced wood.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

T/F Newest tax have floor&roof made of poured concrete on top of metal decking?

A

True
PS roofs also concrete slabs or fibrous material
ALL have poured pitch&gravel covering

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Mezzanines are found in some taxpayers and the ceiling height would be considered?

A

Below average

access wooden stairs or ladder seldom another means of access

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Taxpayers, sprinkler protection for
1938 exceeding ________ ft
1968 exceeding ________ ft

A

10,000

7,500

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Tax. Sprinklers 2008 Group M- mercantile FULL building exceeding _____ sq ft or combined all fl and mezz exceeds _______ sq. ft

A

12,000

24,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Tax. Sprinklers 2008 Group M- Mercantile Occupancy WITHIN a building exceeding _______ sq. ft

A

7500 sq ft. PS same as 1968 code
Also any area of any size 3 stories above grade
Also in HIRI building
Also UNenclosed stair/elevator connecting 2 or more fl.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Tax. Cocklofts Size?

A

4 inches to 6 feet

46 truck has a lot of taxpayers.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Tax. Most common roofs& floors?

A

Tongue&Groove boards
or
Plywood

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What is sometimes found under the tarpaper

of older taxpayers?

A

Tin

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Tax. roof joist are @ approx ______ ft intervals.

A

20’

ps in older truss it is spaced 10-20 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Tax, Why do they invert, raise or reverse roof?
Drainage | ps sometimes an INVERTED roof creates an additional cockloft
26
Trusses 2 major members?
Top chord Bottom chord PS webs in between
27
Tax. What are the most prevalent in modern construction in relation to LW Parallel Chord Truss
Open Web Joist | Steel Bar Joist
28
Tax. Wooden bowstring truss must be put in CIDS. What is abbreviation?
BWSTRG | PS hump like roof. Longer Span= Higher Bow
29
Tax. Testing has concluded that decreased strength in wooden bow string truss may only support ____% of the load originally calculated.
40% | pS this is geared towards the BOTTOM chord
30
Tax. Snow loads would be consider _______ load. | F.F load on roof would be considered _____ load.
Eccentric Live PS FF jumping is an impact load
31
T/F Failure of 1 truss can cause failure of the entire truss?
True
32
Tax. In older truss roof buildings are spaced ______ ft?
10'-20' apart PS beams installed between the truss to support roof covering PS roof joist 20'
33
Tax. Do wood truss roofs get saggy or spongy?
NO, they fail without warning. PS steel-stretches wood-snaps
34
Do open web steel joist have a fire resistance rating?
no | PS rating depends on ceiling finish& finish roofing
35
Steel open web joists span _____ ft?
up to 60 ft | PS planks are staggered and may not end on roof supports.
36
Steel open web joists may collapse in ______ minutes if unprotected.
5-10 min
37
T/F "I" beams protruding above roofs also roofs built in step fashion are good signs of fire walls?
False, the side walls are made of wood sheathing and are detected by striking them with a tool.
38
Tax. Stability of masonry walls are very dependent on ___________.
integrity of the roof (acts as a monolithic brace) Also the load being concentrated in a VERTICAL direction in the wall.
39
Tax concrets walls ______ brick walls _______
hinge | crumble/breaks
40
T/F Front parapet walls are often supported laterally for long distances only receiving support at ends where they tie into crosswalls.
false | UNsupported
41
Tax. When observing walls, place a member where to observe if walls are out of plumb?
corner
42
Tax.T/F Interior partition walls are not fire stopped at the floor & ceiling by wood sills & plates?
False | usually are fire stopped
43
Tax. Canopies/ Marquees 12'x24' marquee 4' deep app. _________ tons of water.
35 | ps attached to inside of building to combustible material Required drainage usually ineffective.
44
Tax. I BEAMS 50' beam @ 970f= ____ stretch 100' beam @ 1000f= _____ stretch
4" | 9 1/2"
45
Tax. When I beams are heated to 1000- 1500f strength drops dramatically these temps can be reached in _________ minutes
5-10 min. | PS for smaller beam sections 30 min to beyond strength limitations.
46
Tax. Will cooling a beam regain its strength?
yes, under normal situations do not hesitate to cool these members. it will contract to original length.
47
Tax. Cast iron columns fail on an average of ____ | minutes.n
about 30 min
48
Tax. Failure of a column is generally ____ serious than a girder or beam.
more
49
Tax. T/F Failure of a column in the cellar can cause the subsequent collapse of the floors and the roof.
True
50
Tax. Suspended ceilings u may find as many as ______ dropped ceilings in a particular store.
2 or 3
51
Tax. Does heavy wire lath & plaster or tin fall as a unit or multiple pieces?
It falls in 1 piece | PS sheetrock hinges in 1 piece
52
Tax, Due to its weight and ability to conceal fire/smoke,What would be the type of floor we are talking about?
terrazzo/concrete sometimes placed over wooden joists
53
Tax. How would u access the basement other than exterior and interior entrances?
paneling under display windows offers vent /steam operation. | PS especially in older types
54
Tax T/F In newer construction concrete floors at ground level and basements are prevalent?
False | with no basement or cellars
55
Tax. Cellar ceilings are required to be fire _______.
retarded but plaster ceilings make it deficient. | PS Partitions between walls in cellars are flimsy so there is no fire stopping.
56
Tax. Security doors in the _____ position give added weight.
OPEN | PS FLUSH type siamese could be cover by these gates.
57
Tax. Doors in RESIDENTIAL installation could weigh | _______.
150 -400 pounds | Commercial will be larger
58
Tax T/F Forcing overhead doors that have lost spring tension makes it easier/
False may be futile
59
Tax. Smaller store have usually how many exits points? | What about larger?
usually 1 | 2 means, costumers only aware of 1
60
Tax Newer type roofs are constructed of what material?
Bar Joists Light Weight Steel Flat Wood Trusses
61
Tax. Who has the greater life hazard during all hours 1 story or 2 story
2 story (Clubs, Dance Halls,etc)
62
Tax. When talking about collapse what must u consider? 3 factors
Type of Construction Intensity of Fire Duration of exposed STRUCTURAL members
63
Tax. Which type of load has the greatest impact? | Impact, Static or Stationary
Impact
64
Read 4.2 Causes/ Warning signs of Collapse
4.2
65
Tax. What would be a major warning sign for collapse? Do not confuse this with causes.
Heavy fire burning out of control for 20 min or more. same goes for an inability to make headway within that time.
66
Tax. 1 cubic foot of brick work weighs about _____?
100 pounds
67
Tax. Would this be considered a cause or a warning sign, spongy/soft feeling on roof?
Warning Sign | NEW 2009
68
Tax. It is recommended to attack a smoke shop with 3 things in mind?
2 1/2 line Extreme Caution Consider knock down from sidewalk
69
Backdrafts 3 basic factors?
Combustibles oxygen heat ( do not fall for fire)
70
T/F Backdrafts dense black smoke is due to lack of o2, small quantities of free carbon and CO.
False large quanties
71
What are the colors associated with backdraft?
dirty brown,yellow brown,gray yellow | and dense black smoke.
72
Tax. What area of the building is particular vulnerable to backdraft?
cellar/storage area | PS u only need 25% of its space to contain the explosive mixture.
73
Tax. What is the most effective way to protect FF from backdraft?
open roof or area directly over the fire. | PS if horizontal is done 1st backdraft is greatly increased.
74
Tax.T/F It may be preferable depending on conditions to vent the front windows and allow the gases to ignite prior to entry?
True (new)
75
Tax . An alternative to roof venting, (not as effective) | is the use of hoseline from where?
Flanking position or reach of stream. | operate line immediately once opened up
76
Tax. When a fire is at its ______ stage it can usually be extinguished with direct attack.
Incipient
77
Tax. All horizontal and initial vert vent is controlled by who?
Ladder Officer PS vent at roof and forcible entry ay street level must be coordinated.
78
Tax. T/F Any change that would affect outcome or structural stability must be reported to sector supervisor?
False | direct to IC
79
Tax. Inverted roof are pitched in what direction?
Front to rear Front&rear to center Front/rear/sides to center PS Mostly high side is in front
80
Tax. Where do most fires originate?
Rear of the 1st floor. Utilities storage and services are located here. Fire will extend to cockloft and this is the lowest portion. (no good)
81
Tax. What are the 2 types of ventilation?
Natural & Mechanical (fans)
82
Tax. What size is roof cut?
8x8 recommended
83
Tax. T/F Trenching, take the returns?
False | leave the returns they can be used as a boundary.
84
Tax. Cutting a hole calls for __ saws and ____ FF's
2 saws | 4 FF
85
Tax. Roof sector supervisor must be assigned when ___ saw operations
MORE THAN 1 Could be Chief or Officer | PS If CRITICAL CUT a chief should be assigned
86
Tax T/F If a roof fails it drops as 1 piece?
False | section by section
87
Tax. When using fog adjust to the width of opening and stand back _____ ft.
4' to 5'
88
Tax, Nothing affects the outcome of a operation as much as _________.
Ventilation.
89
Tax. Wooden joist beams are usually spaced _____ on center
16" | PS flooring and boards are at right angles
90
Tax. Rear extensions usually tie into a larger girder this at times made the rear portion of the added roof _______ the older portion.
Higher than | PS this created a larger void below
91
Tax. T/F The smaller 4x4 segment of the 8x8 can be pulled if necessary.
False never pull until necessary leg cuts are placed in cutting pattern.
92
Tax. At cellar fires cut the 1st floor where?
Near windows away from aisles and doorways
93
Tax T/F You might have to cut the roof for a cellar fire.
True | do not delay this cut
94
T/F Taxpayers with bwstrg truss roof under no circumstance shall a FF operate on the roof with a contents OR structural fire with metal,wood or combination.
True
95
Tax. Exterior ops should be primary tact in 3 situations
Large or advanced fires Timber Truss or underside of roof on fire vacants with bwstrg truss roof
96
Tax. How du u determine if fire is involved in the trusses?
TIC or | Triangular cut in the sloping hip section in the front and/or rear of roof this will provide safety to TL
97
Tax. T/F U can use an exterior stream from TL, this may be directed into these triangular cuts to extinguish fire.
True
98
Tax. When needed to operate on bwstrg truss roof that is NOT on fire the IC must take into account?
Past history of truss failure in these buildings
99
Newer tax, the most common type of light weight open web steel joist are _____?
Corrugated Steel spaced at 4' to 6' apart
100
Tax. Light weight open web steel joists. What are is the roofman allowed and not allowed to do?
Must not cut | remove skylights and scuttle covers
101
Gypsum concrete decking weighs 17.5 cu.ft
False | 17.5 sq.ft
102
What is the vulnerabilty of gypsum concrete?
Moisture White powdery substance NO ROOF OPS
103
Tax. Who do u notify of gypsum concrete?
Roof Sector Supervisor AND IC evacuate the roof Interior ops conduct from areas of safety
104
Tax. Trenching hole is made how wide?
At least 3ft wide in any direction.
105
Tax. Can trenching take the place of vent holes? PS not practical to trench are large area roof that is seriously involved.
no but may serve as an additional vent source.
106
Tax. Who may start a trench where he sees it necessary?
Roof sector supervisor | Mandatory notification to IC
107
Tax. Two handlines on advanced fire in store? | Extension in cockloft,adjoining or advanced fire in cellar? What alarms are these ???'s
extra engine and truck 2nd alarm special call a TL if not on initial response & use is anticipated
108
Tax. A properly placed TL can cover a | frontage of _______?
100ft
109
Sufficient amount of portables to a taxpayer is how many?
Cover all sides and minimum 2 in the front. | Front ladders use as indication of boundaries of building or location of firewalls within building.
110
Tax T/F Consider the use of foam at cellar fires?
False | HI-EX
111
Taxpayers _________ must be given 1st priority.
Life Hazard
112
What must be in position prior to vent and forcing entry to a taxpayer?
sufficient forces required hoselines LCS'S
113
Tax. T/F You can reduce to 1 3/4 after the initial attack?
True as long as compatible to conditions. PS u can use 1 3/4 in exposures if compatible.
114
Tax. What do after the establishment of the initial line?
Supply Sprinkler
115
Tax. If difficulty in making entry what is the next step?
small hole in security door a small triangle shape below the center of the door or removal of window
116
Tax. When can a line be operated in to a trench?
entry delayed/ ceilings impossible to pull. all FF's inside must be withdrawn. lines shut down once interior ops are ready to resume.
117
Tax, There are 1 or more of the following 5 ways for an entrance to cellar?
``` INTERIOR TRAP DOOR interior cellar stair exterior flush sidewalk door exterior stairway horizontal entrance from adjoining cellar. ```
118
Tax. T/F When there is interior stair to cellar, especially open stair, and conditions permit 1st line must be stretched to to this point.
True PS 2nd line must come to this point if 1st line goes down.
119
Tax. Can u use fog at cellar fires?
Yes, with discretion inadequate vent is a problem.
120
Tax. If u can not get line down stairs what is the next option?
Front or rear exterior entrances but not opposite each other
121
Tax. If ______ lines advancing in unison do not control the fire heavy outside streams will be required>
2
122
Tax. What is the last resort for a cellar fire?
Flooding 1st floor with stang or TL
123
Tax. Who ensures sprinkler is supplied?
3rd due engine | ACRO- TAX-PAY-ER 3
124
Tax. Can 1st line supply sprinkler?
yes if manpower and conditions permit
125
Tax. T/F 2nd engine assist 1st eng,stretch 2nd line if possible after supplying sprinkler. Supply sprinkler if manpower & condition permit?
True
126
Tax. T/F For a store fire bring the first 2 lines in through the front door?
False Through the windows leave the doorway for fleeing occupants. PS additional lines to adjoining or roof
127
Tax. Cockloft fires, put this in the proper order? pull ceilings vent roof stretch lines into occupancies
vent roof pull ceilings stretch lines into occupancies
128
Tax. What kind of lines do u use from the roof?
Cellar pipe Distributors NY Bent Tip PS protective lines should be in place
129
Tax. Can u operate lines into the roof?
Generally not good practice. Interior ops have to cease & FF to safe area Remember older type build remove signs
130
Tax. What are the 3 major problems with cockloft fires?
Serious exposure to adjoining especially LEEWARD SIDE. Collapse Ducts spreading smoke,fire,gases
131
Tax.T/F Store fire 2nd engine can stretch a second line as a back up for the 1st line or into exposure.
True | PS may have to skip stores
132
Tax. Cockloft fire& exposure protection CRITICAL 1st engine does what?
1:deckpipe ILP will allow positioning for ladder 2:stretch handline to most seriously exposed build PS exposure not critical 1st line to store
133
Tax. 2nd engine, Fire has control of the cockloft& exposure protection is critical. What do u do?
Assist 1st engine with 1st line | if staffing permits stretch a line to most severe exposure& operate into cockloft to confine/extinguish
134
Tax T/F in relation to cockloft fires there is no mention of 1st&2nd attempting to supply sprinkler
True | PS 3rd ensures sprinkler
135
Tax. Primary duty for ladder companies is____?
Life Safety
136
Tax T/F Many 2nd fl occupancies do not have a second means of egress.
True
137
T/F Taxpayer windows may be barred with steel or wood.
True
138
Tax T/F 1st ladder locates & ID's the fire?
True unless attending a life hazard then 2nd due would do 1st dues job.
139
Tax. TL may have to be positioned______ above street level.
1 to 2'
140
Tax. If high heat on the 1st fl and no visible flame AND smoke in many stores,What must u assume?
Cellar fire | PS adjoining cellars must always be checked
141
Tax. No cutting of floors until ________.
protective hoseline in place. | cut near windows or under skylights
142
Tax. T/F Smoke ejectors can be placed over holes cut in floors or hung in openings close to the entrance through which the line is advancing.
False | openings remote to entrance.
143
Tax. Cellar fire, Forcible entry team 1st due shut utilities and are required to do what else?
Vent rear from INTERIOR when possible. take show windows in front of cellar with IC app. Vent as necessary after communicating with 1st ladder officer. Force cellar and store entrances.
144
Tax. 2nd due forcible entry team goes where for cellar fires?
Adjacent stores & cellar entrances for extension
145
Tax. 1st due roof for a cellar fire, does he bring saw to the roof?
No Portable to roof, vent scuttles etc monitor conditions
146
Tax. 2nd due roof for a cellar, does he bring saw to the roof?
Yes | If not required on the roof perform as directed.
147
Tax. 1st due OV for cellar fire, where does he pay particular attention too? Who does he notify if entry is made?
1st floor rear Officer PS check rear/sides vent cellar/store from rear also team up with 1st OV or other
148
Tax. 1st due LCC for cellar fire if u are in a TL. Where du u place apparatus?
Front of fire building | 1 TL per street front
149
Tax. 1st and 2nd due LCC's for a cellar fire if u are in an aerial. Where do place APP and where do u go?
Place APP away | Join inside team if not directed otherwise
150
Tax. Most store fires start in the store at street level, | what part of the store are we talking about?
Storage/Utility Area | usually in the rear of 1st fl.
151
Tax. What type of partition walls usually separate stores in the same building?
LIGHT
152
Tax. Store/Cockloft fires is it good practice to probe the ceiling with a hook?
yes
153
Tax. If u are to vent store windows what must be done?
Must have CHARGED line in | place authorized by IC
154
Tax. When dealing with ducts would u consider the the insulation flammable or non-flammable?
non-flammable with paper covering that may cause extension. | PS SHUT DOWN FAN MOTORS
155
Tax. Most fires extend through to the cockloft from the store OR cellar through______?
ceilings vertical arteries ducts
156
Tax. Cockloft fire make _____ ______ to see if fire has reached other portions of the roof.
Examination Holes | PS also helps to mitigate backdraft
157
Tax trenching depends on 3 things?
size of roof volume of fire ceilings (height/type)
158
Tax. 2nd due forcible entry team shuts utilities?
no | 1st due forcible entry team shuts utilities
159
Tax 1st due forcible entry does what at store/cockloft fires?
``` force entry locate fire control life hazard search store SHUT UTILITIES ```
160
Tax. Where does 2nd due forcible entry team go for store/cockloft fires?
adjacent stores | VES as necessary
161
Tax.1st Roof FF store/cockloft fires 1st due does what and brings what tools?
portable to roof. vent scuttles/skylights Saw and Hook
162
Tax. 2nd due roof FF for store/cockloft brings what tools?
Saw with axe or iron
163
Tax. 1st due OV for store/cockloft does what and brings what tools?
check rear and sides for access. VES if possible MAUL&HALLIGAN
164
T/F Tax 2nd due OV for store/cockloft goes to the roof?
He can team up with 1st OV or go to go to roof
165
Tax.1st due LCC of aerial usually places app away from building. When would be a time LCC extends it to the roof?
Fire extends to cockloft. | PS 2nd LCC places away& joins inside team.
166
Tax. Tools for forcible entry team. Can ? Irons?
Can-Can/Hook Irons- Axe/halligan Maul&Duckbill may be needed Saw With Aluminum Oxide blade (apex to top)
167
Tax. Tools for the OV?
Maul& Halligan | hook&axe inadequate
168
Tax. Tools for the roofman?
Saw with HOOK | Subsequent members axe OR halligan with saw if available
169
Tax. What size hooks must be anticipated?
10 12 15
170
Tax. Who reports in with the 10 and 12 ft hooks?
Trucks other than 1st and 2nd due in addition to there regular tools.
171
Tax Dance hall on the 2nd floor would usually have what type of stairway?
LARGE Open Stairway
172
Tax. T/F Limited penetration of LCS if 2nd fl. is divided into multi-occupancy use?
true
173
Interior ops at a taxpayer when would u consider illumination?
both Day and Night
174
Taxpayer what is the single most important factor?
Construction Features
175
Tax. 1938 code. Has a max Sq footage for street fronts. 1 street front _______ 2 street front _______ 3 street front _______
1= 10,000 sq ft 2= 14,500 sq ft 3= 17,500 sq ft PS IF Sprinklered DOUBLE those numbers
176
Tax. 1938 code. Concealed roof spaces to be cut into areas of _________ sq ft or less by fire stops
3000 sq ft | PS. Wood purlins & Cross braces used for suspended ceilings 2000 sq ft or less.
177
Tax. 1938 code. Cellar ceilings are to be ______?
Fire retarded
178
Tax. 1938 code. 2 adjoining stores may be covered by 3 things?
unenclosed stairway open well escalator
179
Tax. 1938 code. Openings on a lot line to have at least ________ minutes of protective assemblies.
45 min
180
Tax. 1968 code. What is the max sq ft if unsprinklered ?
7500 sq ft. | PS No limit if sprinklered must have siamese
181
Tax 1968 code. Construction class. IIB = non combust ext. walls with _____ wood joist. IIC= non combust ext. walls with ______ wood joist.
protected | UNprotected
182
Tax. 1968 code. What size sprinkler system requires a siamese?
EXCEEDING 7500 sq ft
183
Tax. 1968 code. Unsprinklered concealed roof spaces to be cut into areas of _____ sq ft or less by fire stops.
3000 sq ft or less
184
Tax. 1968 code. T/F Fire escapes are prohibited in new buildings.
True only allowed in altered buildings with special permission.
185
Tax. 1968. Parapets are required on exterior walls in buildings over ______ ft & if roof is of combustible material parapet @ least _____ ft.
OVER 22ft | at least 2ft