Positions Flashcards
TAXPAYER
Store Fire or COCKLOFT Fire
2nd due ROOF
2nd due ROOF
SAW (second saw to roof)
Ax OR HALLIGAN
Portable to roof. ( second portable to roof)
TAXPAYER
STORE FIRE or COCKLOFT FIRE
1st DUE ROOF
1st due ROOF
6ft hook and SAW
PORTABLE LADDER to ROOF
PRIVATE DWELLING
ROOF POSITION
FLAT ROOF
ORDER OF PREFERENCE
T A P TOWER LADDER AERIAL LADDER PORTABLE LADDER TOOLS HALLIGAN 6FT HALLIGAN HOOK LSR
PRIVATE DWELLINGS
2nd Due ROOF
FLAT ROOF
T A P ( way to roof)
2nd due Roof
HOOK and SAW (1st saw on roof)
PRIVATE DWELLINGS
PEAKED ROOF
1st due ROOF 1st due OV TEAM TOGETHER TOOLS PORTABLE LADDER 6ft Hook AND/OR HALLIGAN EACH FIREFIGHTER
Roof ops are not an INITIAL CONSIDERATION at PEAKED ROOFS
BROWNSTONES/ROWFRAMES
1st due ROOF
Aerial Aerial Adjoining 1st due ROOF HALLIGAN 6FT HALLIGAN HOOK LSR
BROWNSTONES/ROWFRAMES
2nd DUE ROOF
Aerial Aerial Adjoining
2nd Due Roof
6FT HALLIGAN HOOK and
HALLIGAN
BROWNSTONES/ROWFRAMES
TOP FLOOR FIRE
1ST DUE ROOF
1st due roof Top floor fire HALLIGAN 6ft HALLIGAN HOOK and LSR
LCC raises to ROOF of ADJOINING BLDG for ROOF and OV
BROWNSTONES/ROWFRAMES
TOP FLOOR FIRE
1st due OV
1st due OV
SAW and
HALLIGAN
LCC raises to roof of ADJOINING BLDG for ROOF and OV
BROWNSTONES/ROWFRAMES
TOP FLOOR FIRE
2nd DUE ROOF
2nd Due ROOF
TOP FLOOR FIRE
SAW and
6ft HALLIGAN HOOK
LCC raises to ROOF of ADJOINING BLD for ROOF n OV
BROWNSTONES/ROWFRAMES
TOP FLOOR FIRE
2nd DUE OV
2nd due OV
TOP FLOOR FIRE
6ft HALLIGAN HOOK and
HALLIGAN
WILL VENT THE FIRE APT
BROWNSTONES/ROWFRAMES
TOP FLOOR FIRES
1st n 2nd
ROOF N OV
1st ROOF HALLIGAN,6ft HALLIGAN HOOK and LSR 1st OV HALLIGAN and SAW 2nd ROOF 6ft HALLIGAN HOOK and SAW 2nd OV 6ft HOOK and HALLIGAN
TENEMENTS
1st due ROOF
BAR (adjoining BUILDING,AERIAL,REAR FE)
HALLIGAN
6ft HALLIGAN HOOK
LSR
TENEMENTS
2nd DUE ROOF
BAR (adjoining BUILDING,AERIAL,REAR FE)
HALLIGAN
6ft HALLIGAN HOOK
LSR
Contacts 1st due ROOF
1) method of access to roof
2) problems encountered
3) need for assistance
4) need to seek alternate route
TENEMENTS
TOP FLOOR FIRE
1st due ROOF
BAR (adjoining building,Aerial,Rear FE)
HALLIGAN
6 ft HALLIGAN HOOK
LSR
TENEMENTS
TOP FLOOR FIRE
1st DUE OV
BAR (adjoining BUILDING,AERIAL,REAR FE)
HALLIGAN and
SAW.
TENEMENTS
TOP FLOOR FIRE
2nd DUE ROOF
BAR (adjoining BUILDING, AERIAL,REAR FE)
6fT HALLIGAN HOOK and
SAW
TENEMENTS
TOP FLOOR FIRE
2nd Due OV
BAR
6ft HALLIGAN HOOK and
HALLIGAN
2nd Due OV VENTS FIRE APT
HRFPMD ( 10-77)
1st n 3rd due ROOF
FLOOR ABOVE via ATTACK STAIRWAY HALLIGAN HYDRA RAM KO CURTAIN
HRFPMD (10-77)
2nd DUE ROOF
FLOOR ABOVE via ATTACK STAIRWAY HALLIGAN and MAUL LSR LIFE BELT
LRFPMD
1st n 2nd due ROOF
ROOF OF BUILDING BEST B (building attached preferred,adjoining,FIRE DOORS) ES (enclosed evacuation stairway) T (trucks Aerial OR TOWER ladder
HALLIGAN
HOOK
LSR
LRFPMD
TOP FLOOR FIRE
2nd due ROOF
BEST TOP FLOOR FIRE HALLIGAN HOOK KO CURTAIN
LRFPMD
TOP FLOOR FIRE
2nd Due
INSIDE TEAM
Associated TOOLS
and
KO CURTAIN
HR OFFICE BUILDINGS (10-76)
1st due LADDER COMPANY (5 guys)
2nd due LADDER COMPANY (5 guys)
SEARCHING FIRE FLOOR
NO TOOL ASSIGNMENTS
HR OFFICE BUILDING (10-76)
3rd due LADDER CO. (5 guys)
Searching FLOOR ABOVE
No TOOL ASSIGNMENTS