Engine Opps CH 1-5 JIMMY Flashcards
All engine company FFs should be able to perform the following functions except?
A) transfer the engine from road to pump
B) connect the apparatus to a hydrant using each of the several connections available and standard hose
C) charge and maintain adequate pressure on a hose line using the pump panel controls
D) know how to drive the rig in an emergency
Who is responsible to force entry in the event that the assigned ladder company is delayed?
Engine companies should designate a member to perform forcible entry
Who decides where to position the apparatus once the fire location has been determined?
The officer
When performing a backstretch where should the engine company stop?
An engine company should stop past the fire building to perform a backstretch. After FFs remove sufficient hose to reach the fire, engine apparatus backstretches, dropping hose as it proceeds to the hydrant. This allows the ladder company to take a tentative position upon arrival.
When does the ladder company enter the block first?
If the fire building is located at the end of a narrow dead end road
In winter ops, if 3 stories or less engine enters block first
If higher than 3 stories ladder enters first
Can you stretch more than 2 hand lines from a pumper?
In an emergency you can stretch 3 hand lines from a pumper and the supply or operating pumper shall be augmented as soon as possible to ensure that positive water is maintained and the IC shall be notified
T/F the supply pumper in a relay operation can only supply 1 other handline.
False. The supply pumper In a relay should not supply any hand lines or large caliber streams.
T/F the pumper supplying a large caliber stream should not supply any hand lines or additional larger caliber streams?
True
What is the primary consideration at any fire ground operation?
The protection of life
T/F life saving operations are placed ahead of firefighting when sufficient firefighters are not available to do both
True
A life hazard visible upon arrival must be addressed. Can the first arriving engine make immediate rescue attempts without stretching a hose line?
Yes, immediate rescue attempts by the first arriving engine company without simultaneously stretching and positioning a hose line should be attempted only in EXTREME situations.
What are progression of the modern contents fires (stages)
Incipient
Rapid growth stage that consumes available oxygen very quickly
Ventilation limited early decay
If additional oxygen is added a more rapid and intense 2nd growth
ventilation induced flashover transitioning to fully developed
2nd decay
When fire begins to spread across the ceiling of the fire compartment, this is known as what?
Rollover
This rollover is an indicator that fire conditions are rapidly changing. When rollover occurs any member not operating under the protection of a charged line should do what?
Immediately leave and isolate the fire area
T/F as modern contents fires rapidly consume the available oxygen, the fire can go into an early decay stage prior to reaching fully developed.
True