Line Placement: Brown/ Rowframe/ PD's Flashcards
Brownstone. Cellar fire. 1st line goes where?
1st fl then down interior stairs cellar stairs to extinguish fire. If 1st line is used to secure 1st fl then 2nd line goes to cellar.
Brownstone cellar fire 3rd line goes where?
If necessary stretched as ordered by IC
Why do u stretch 1 3/4 lines in brown/rowframes?
Speed
Mobility
Close quarters
Brownstones 1st floor fires 1st line goes where?
Through 1st fl.to extinguish fire
Brownstone 1st floor fire 2nd line, if not needed to back up 1st goes where?
Stretched through 2nd fl to maintain integrity of interior stairs.
PS Row Frames 2nd line goes above also if not needed to back up 1st
Brownstone 1st floor fire 3rd line goes where?
If necessary as ordered by IC
Brownstone. fire on upper floor 1st line and 2nd goes where?
1st line through parlor to the fire floor
2nd line through parlor to back up 1st line.
PS if needed as ordered by IC
Brownstone. Fully involved. What should the 1st engine do before stretching into fire building?
Fully involved drop 2 hoselines in front and position apparatus for possible multi or supply for TL
Brownstone. Fully involved. Where do 1st and 2nd lines go?
1st into the fire building
2nd line backup 1st.
Brownstone. Fully involved. As we know 1st and 2nd lines go in together as a team and 3rd line goes where?
Advance in fire building or
fire reported in exp. stretched to that exp. or
no fire in exp. stretch through an exposure in the rear yard of the fire building.
Rowframe. Cellar fire,1st line?
Through the front door then to cellar via interior stairs.
IF too hot protect public hall, interior stair and hall.
If 1st line goes to top fl AFTER cellar controlled by 2nd. Check intermediated fls and FF on landing watching for fire that may break below them.
Rowframe. Cellar fire 2nd line?
Back up 1st.
If not needed to back up 1st then put out any fire on 1st fl then advance to top fl checking intermediate fls.
IF 1st line cover 1st fl public hall + back up not needed 2nd line stretched OUTSIDE cellar ent.
Rowframe. Cellar fire 3rd line?
If needed it will be ordered by the IC
Rowframe. 1st fl fire 1st line?
To location of fire.
Rowframe. 1st fl fire 2nd line if not needed to back up 1st line?
Above the fire
PS same in brownstones stretch through parlor floor
Rowframe 3 window front. 1st fl fire. 1st line is stretched through the 1st fl, 2nd line goes?
if not needed to back up 1st go through the front door ON THE SECOND FL. to maintain interior stairs.
PS same as brownstones
Rowframe. 3 window front. 1st fl fire. 3 rd line goes where?
IC orders it to. Fire building Exposure Supply TL Through an exposure to rear yard
Rowframe. Upper floor fire. As we know 1st line is going to the fire and enough line needs to cover ENTIRE BUILDING. If 2nd line not needed to back up 1st then?
top fl. or floor above.
If fire in exp. it may be more effective to stretch to exp. with 3rd and 4th to back up 1st hose.
This hose needs to cover ENTIRE build.
Rowframe. Upper fl. fire. 3rd line?
Ordered by IC fire building exposure Supply TL Through exp to rear yard
Rowframe. Fully involved + fire in exp. Holding Ops. 1st engine drops what?
1- 3 1/2 for TL and handline for building.
Prior to TL multiversal on pumper or heavy caliber stream consideration given to life hazard and need for advancement to interior hoseline.
Rowframe Fully involved and fire in exp. 1st hand line goes where?
through the front door to fire building
Rowframe. Fully involved and fire in exp. 2nd line if not need to back up 1st line goes where?
Top fl of most severe exposure.
PS check intermediate floors
Rowframe. Fully involved and fire in exp. 1st and 2nd line are in fire building 3rd line goes where?
Top fl of most severe exposure.
PS if 2nd line in exp then 3rd goes to opposite exp.
Rowframe. Fully involved and fire in exposures 4th line goes where?
Stretched and ordered by IC
Rowframe. Vacant building in a row of OCCUPIED frames, 1st engine drops what and goes where?
1 handline for the MOST SEVERE EXPOSURE
1 line for TL
Rowframe. Vacant building in a row of OCCUPIED frames, 2nd hoseline not needed to back up 1st goes where?
stretch to fire building OR opposite exp.