Service Gases-Nitrogen Flashcards
What is nitrogen used for at the plant ?
Used for:
-Blanketing
-Pressurizing
-purging
-Backup for various systems
What pressure does nitrogen system supply nitrogen at ?
High pressure-650 psig
Low pressure -115psig
What systems or components uses High Pressure Nitrogen for Pressurizing ?
-Safety Injection Tanks(STIs)
-Atmospheric Dump Valves(ADV)accumulator
-SG Downcomer Feedwater Isolation Valves(FWIV) &Control Valves Accumulator
What system uses High Pressure Nitrogen to open?
Downcomer Feedwater Isolation Valves(FWIVs)
What components use High Pressure Nitrogen as backup to Instrument Air for Operating ?
-Atmospheric Dump Valves(ADVs)
-Downcomer Feedwater Control Valves
-Downcomer Feedwater Isolation Valves(FWIVs) Pneumatic Positioning Valve
What surge tanks does Low Pressure Nitrogen blanket ?
-Turbine Cooling surge tank(TC)
-Nuclear Cooling surge tank(NC)
-Essential Cooling surge tank (EW)
-Essential Chilled surge tank (EC)
-Norm. Chilled surge tank(WC)
What storage/drain tanks does Low Pressure Nitrogen Blanket ?
-Condensate Storage Tank(CST)
-Demon. Water Storage Tank(DWST)
-Equipment Drain Tank
-Reactor Drain Tank
-Volume Control Tank(VCT)
-Boric Acid Concentrator(BAC)
-Steam Generators
What systems uses Low Pressure Nitrogen Purging ?
-Volume control tank
-CVCS gas stripper
-Liquid Rad. Waste Evaporator (LRS)
-Boric Acid Concentrator Vent Cooler (BAC)
-Reactor Coolant System pressurizer
-Equipment Drain Tank(EDT)
-Reactor Drain Tank(RDT)
-Main Condenser
-Feedwater Heaters
What does Low Pressure Nitrogen serve as backup for ?
Serves as a backup to Instrument Air (AI)supply header
What’re the major components of the Nitrogen System ?
-Liquid Nitrogen Storage Tank
-Two Liquid Nitrogen Pumps
-Low Pressure Nitrogen Vaporizer
-High Pressure Nitrogen Vaporizer
-Nitrogen Gas Storage Cylinder
-Regulating Valves
What is flow path for Low Pressure Nitrogen ?
1.)Storage Tank
2.)LP Ambient Vaporizer
3.)LP Header
4.)Flow through 1of2 PCV/regulating valve
5.)LP header loads
What is the normal and backup pressure for LP header loads?
Normally-115psig
Backup-105psig
What is flow path for High Pressure Nitrogen ?
1.)Liquid Nitrogen from storage tank to liquid Nitrogen pumps
2.)HP Ambient Vaporizer
3.)Storage Banks
4.)Each Storage supplies one set of PCV/PRV to maintain HP header
-Active Bank :650psig
-Reserve Bank :630psig
What is Liquid Nitrogen Storage Tank used for ?
-Used to storage Nitrogen for LP and HP headers
-Storage Capacity designated to provide adequate to permit refueling shutdown and subsequent starts
What is the net Capacity & what is the pressure that the Liquid Nitrogen Storage Tank is kept at ?
Net capacity- 3082Gallons but is maintained @85% full
Pressure- rated for 245psig but is maintained @ 150-160psig
What is the inner and outer cylinder designed for in the Liquid Nitrogen Storage tank ?
Space between inner and outer cylinder is maintained at vacuum and filled with insulation to help maintain pressure inside tank
How often is Liquid Nitrogen storage tank refilled ?
-Filled twice per week from trailer while at power, or as needed during outage
-Top fill valve & Bottom fill valve
When being refilled what pressure is tank supposed to be maintained at ? How full should it be filled ?
-Tank should be maintained between 150-160psig
-Should be filled to 85% full(where tank liquid overflow line is)
What happens when tank is refilled via bottom valve ?
Causes tank pressure and level to rise
What happens when filling tank via Top fill line ?
-Spray valve causes gas at top of tank to condense and lower pressure and raise level
What happens if Nitrogen Storage Tank level drops below 150psig ?
Nitrogen Tank Buildup Regulator opens and Pressure Build Coil vaporizes portion of nitrogen and returns it to top of tank to buildup pressure between 150-160psig
What happens when Nitrogen Storage Tank Pressure raises above 160 psig ?
Tank Vapor Space Back-pressure Control Valve opens, bleeds gas from top of tank to liquid supply line to LP vaporizer, lowers tank pressure
What is safety relief valve pressure set-point for Nitrogen Storage tank ?
-Safety Relief Valve pressure setpoint is 245psig
-Rupture disc for protection from over pressurization due to excess liquid vaporization
What is maximum tank operating pressure? What happens if that pressure is exceeded?
-Max. Operating pressure is 220psig
-If 220psig is exceeded AO must manually vent tank to lower pressure
What does Liquid Nitrogen Control Panel do for Nitrogen system ?
-Provides controls, indications, and alarms for HP Liquid Nitrogen Pumps & associated solenoid operated valves
What does PLC do for nitrogen system ? What’re the two types of PLCs between the 3 units ?
-PLC monitors and actuates in High Pressure Nitrogen system
Two types of PLC:
-Modicron Programmable Logic Controller
-Allen-Bradley Programmable Logic Controller
What do the PLCs monitor ?
-Liquid nitrogen storage tank level
-HP Nitrogen Header temperature downstream of vaporizer
-HP Nitrogen Active Bank pressure
What is the Two position(On/Off) Main Power switch used for ?
It gives power to Control Panel and PLC
What is the Two Position selector switch(A/B) pump for ?
-Provided to select which HP Liquid Nitrogen Pump to be in service
-The selected pump will energize on a start signal
What is Start Pushbutton for ?
One start Pushbutton is provided to start selected HP liquid Nitrogen Pump
What is Override Pushbutton used for ?
Provided to override automatic operation of controller and manually start HP Liquid Nitrogen Pump
What light indications are provided for the pump ?
-‘A’ pump running
-‘B’ pump running
-Pump standby
-Cooldown
-Pump override
What alarm indications and controls does the Liquid Storage Tank Provide ?
-Low level in tank
-Low temp. In the HP Header between HP Vaporizer and Storage Banks
-High Pressure in Active Bank
What cools the PLC inside the control panel ?
Small amount of nitrogen pulled out of LP header, which goes through PCV, then to the Control Cabinet & PLC
What’re the High Pressure Liquid Nitrogen pumps used for ?
Transfer liquid Nitrogen from storage tanks to HP vaporizers, which is then stored in HP Nitrogen storage banks
What kinds of pumps are the HP Liquid Nitrogen pumps?
Reciprocating positive displacement pumps
When will the PLC send a start signal to the standby HP Nitrogen Pump ?
When HP Nitrogen Bank drops to 1400psig it’ll send a start signal to standby pump
How would you manually start pump if Active Bankpressure is between 1400psig-2100psig ?
1.)Push override button,which will illuminate override light
2.) Push start Pushbutton to send start signal to pump
Which solenoid valve opens when the HP nitrogen pumps receive a start signal ?
The Solenoid operated Inlet Valve opens to allow flow from liquid nitrogen storage tank to the HP pumps