Control Power 125VDC (PK) Flashcards

1
Q

Where does PK system receive its power from ?

A

It receives it from a Class 480 MCC (PH)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many channels of control power is there ?

A

4 channels A,B,C,D

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What kind of equipment did each PK train have?

A

-Battery (each channel)
-Battery charger(each channel)
-Swing battery charger (Each Train)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What do the ‘A’ & ‘B’ CHANNELS provide control power to?

A

-Train A & Train B
-vital instru. And control power for channels A &B RPS
-ESF system
-Diesel Generator A & B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What do C & D channels provide instrument. & control power to ?

A

RPS & ESF systems and other safety loads

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What happens if AC or DC breaker is opened on battery charger ?

A

B01 will receive alarm in control room & plant computer (NOT SWING CHARGERS)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What’re provided on 480 MCC for battery chargers to B,D,BD( Train B) ?

A

A disconnect switch that will isolate from control room in case of a control room fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is used to prevent moisture in the battery chargers ?

A

Space heaters controlled by thermostats

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What will an operator have to do to investigate a an alarm on battery charger ?

A

Operator will have to open cabinet and investigate the LED indications

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How do you swap class battery chargers ?

A

-Remove in service battery charger and place oncoming battery charger.

-Class battery chargers should NOT be place in parallel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What’re the purpose of the Class batteries ?

A

2 hours of DC power to class loads during a LOCA,LOP, or design basis event

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

During a station blackout what will happen for Class loads that are powered from PK?

A

First hour Class batteries will power class loads, then once SBOGS are in service A train battery chargers will be loaded on

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How does PK interface with PN system ?

A

PK send 125VDC power through inverter and changes it to 120VAC to supply PN instrument power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What indication do you look for on an under voltage on a class control center?

A

A local white light indicator and a alarm in control room

-Alarm will self reset when conditions clear

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What indication do you look for on a ground bus condition of a control center ?

A

-White light will illuminate and alarm will be on in control room

-The “ground reset” button will reset alarm and indication

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What will happen if battery breaker is closed, while racking screw cover interlock is open ?

A

The battery breaker will trip due to cover being open

17
Q

Which channels do the battery breakers have transfer switch on ?

A

Channels A,B,C battery breaker

18
Q

How does PKA system interface with diesel generators ?

A

Provides control power and field flashing power

19
Q

How does PK interface with AF?

A

Supplies control power to MOV & Electronic Governor Regulator

20
Q

How does PK interface with Oily Waste(OW)?

A

OW provides drains for each battery room for 1 of 2 neutralizing sumps (One per train)

21
Q

How does PK interface with SG?

A

Provides control power to MSIVS logic cabinet

22
Q

How does PK interface with Safety Injection?

A

Supplies control power through inverter to motor operated Shutdown Cooling Containment Iso. Valves

23
Q

How does PK interface with Containment isolation ?

A

Provide control power to containment isolation valves