CTS and H2 Recombiners Flashcards
What is the purpose of the CTS system?
- Limits post-accident containment pressure and temperature to less than design values of 12#
- Removes radioactive elemental iodine from the containment atmosphere in the event of a DBA.
What is the purpose of the H2 Recombiner?
- Control the hydrogen generated in the containment after a loss of coolant accident (LOCA)
What is the purpose of DIS?
- The DIS eliminates hydrogen in the containment following a LOCA to prevent a detonation by period ignition of h2 mixtures
What are the ESF systems in the plant?
- Ctmnt Structure
- ECCS System
- Ice Condenser
- CTS
What are the CTS pump starts?
- Load Shed (W/ Phase B)
- Phase B
- Manual
What are the CTS pump Trips?
- Load Shed
- Overload/Overcurrent
- Manual
What causes a CTS signal?
- 2.8# (2/4)
What are the fission product barriers?
- Fuel Clad
- RCS
- Ctmnt building
What do you declare if you lose one or potential to lose one fission product barrier?
- Unusual event
What do you declare if you lose two fission product barriers and potential to lose a thrid fission product barrier (Fuel Clad or RCS Barrier)?
- General Emergency
What do you declare if you lose any TWO of the following:
- Loss or Potential Loss of Fuel Clad.
- Loss or Potential Loss of RCS.
- Loss of Containment Barrier.
- Site Area Emergency
What happens on a SAT low-low lvl?
- SAT outlet valves close and eductor suction valves should have closed prior to the SAT Low Low lvl alarm but it sends the signal again
What is the CTS flow to upper ctmnt spray header?
- 2000gpm
What is the CTS flow to lower ctmnt spray header?
- 1200gpm
Which CTS header does RHR feed and how much flow?
- Upper ctmnt spray header only, and 2000gpm