BC chapter 9 Flashcards
unrestrained steel beam 20 feet long can
expand 1.4 inches significantly pushing at lateral constraints
steel column encased in 3 inches of concrete with a siliceous aggregate would have a fire resistance of
4 hours
spray-applied fire-resistive materials (SFRM)
spray foam insulation
applied fireproofing can vary from 7/8 to 1 7/8 to produce fire-resistive rating of one to four hours
Intumescent and mastic coatings
will char,foam,and expand when heated …the material will expand to fifteen to thirty times its original volume
open web joists are mass produced and are available with
depths of up to 6 feet and a span up to 144 feet ….more frequently found with depths less than 2 feet and spans of 40 feet
Steel rigid frames usually are
used for spans from 40 to 200 feet and are fabricated by welding or bolting together steel shapes and plates
Steel arches
constructed to span distances in excess of 300 feet
primary purpose of a gusset plate
is to strengthen the connection and increase the steel mass at the connection