DOOR FAULTS Flashcards
On what unit would you find:
- PERV?
- PERH?
- B92
- B2007
Would ADC be lost if PERV has been pulled and doors are still in contact?
NO
List 2 ways you can carry out DOOR ENABLING TROUBLESHOOTING
- Check correct train positioning on Docking Board
- Verify door activation status in other carriages
If you overshoot docking board, what must you do?
- Contact control and await for instructions
- Select E/S with permission and dock correctly if within platform
- If not in confines of platform, with permission change ends, select E/S, dock correctly and enable doors platform side
What can you do if you stop short?
Select ATP MANUAL with prior permission
What are your initial steps if NO ADC at a station?
- Re-enable doors
- Make announcements
- Try to do door procedure TWICE
What should you do if after carrying out initial steps to solve ADC, the issue hasn’t been fixed?
- If NO ADC, check PTI for visible obstructions
- If obstruction seen, place inhibit, walk to door, remove obstruction, notify Control and log
2A. If no obstruction, inform control about ADC issue - Control may ask to check all doors - walk along platform and press door push button in each door
- Monitor ODI on B92 and B2007
- ON B92 PUSH BUTTON IS INACTIVE IF DOORS ARE NOT FULLY CLOSED
- ON B2007 CHECK HMI FOR FAULTS - If door fault, contact control, door isolation may be requested.
- Tell Control of location, run number, vehicle number, door numbers and nature of fault
- If no issues, close doors
- Control will ask you to check PERV/PERH at each door if ADC issue persists
What happens to your train if you lose ADC between stations?
The Emergency Brakes will apply
How can you find out of a door fault on a B2007?
By Checking the HMI
What are your actions should you lose ADC between stations?
- Report ADC loss to control with full details
- Make announcement to stand clear of doors and not lean on them
- Follow controller instructions and check all doors
- Apply INHIBIT AT DCP and walking through train pushing each door slightly open and allowing it to close
- Verify PERV/PERH status and observe ADC lamp after every door has opened and closed
(IF PERV/PERH HAS BEEN ACTIVATED FOLLOW CONTROLLER INSTRUCTIONS)
- Allow train to continue if ADC has been acquired
- Contact Control if set of doors has been found OPEN and follow instructions
7A. Contact Control if doors are CLOSED but no ADC, follow instructions and update notebook
Define DOOR IRREGULARITIES
They are faults related to door safety system that happen in AUTO/ATP caused by circuits or train related issues
Give 2 examples of doors irregularities
- Enabling doors non platform side between stations
- Trains moving with open doors
What happens to trains who are subject to a door irregularity and why?
These are immediately taken out of service and moved to depot for investigation, this is because they can significantly cause risk to customer safety
How would you deal with a DOOR IRREGULARITY
And what will be your actions post event?
- Apply INHIBIT if train moved with open doors
- Contact control using emergency channel
- Provide detail information about the irregularity
- Follow Controller instructions
- Prioritise customer safety
- Control may ask you to isolate doors non platform side
- Prepare and submit IRF due to irregularity
2.. Attend de-brief with Rolling Stock technician
What are reasons for door isolation?
- Door stuck open
- Door stuck closed
- Slow Door Closing
- Not enabling doors
- Controller Request
- Air leak B92 door
- Obstructed doors not resetting on B2007