Water Power Calculator Flashcards

TRA00282

1
Q

How many lobes are in ATR and how many fuel elements in each?

A

There are five lobes in ATR (NW, NE, C, SW, SE). Each lobe contains eight fuel elements.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many fuel elements per baffled-separated quadrant?

A

The flow distribution is divided into four quadrants including 10 fuel elements per quadrant.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the purpose of the Water Power Calculator?

A

ATR lobe powers are determined by data from WPC and N-16. Output of these two systems is reduced by RDAS yielding lobe powers. The WPC is effectively the calibration standard for the lobe power indication.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Is WPC safety-related?

A

Lobe power indication is safety related since the safety analysis uses lobe power.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What specific powers are calculated by WPC?

A

Total Thermal Power
Quadrant Thermal Powers (4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How many channels does WPC have?

A

Two Channels:
WPC-1
WPC-2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the purpose of the WPC Selector Switch?

A

SS HS-1-1 selects which data is displayed on RCR recorders.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the power supplies for WPCs?

A

WPC-1 from 670-IP1 (Inst. Panel Ch.1)
WPC-2 from 670-IP2 (Inst. Panel Ch.2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What are the input signals to the WPC?

A

10 Input signals in total to WPC:
Reactor Inlet Temp (Average of 4 instruments) - 1 input
Quadrant Outlet Temps - 4 inputs
Reactor Outlet Temp - 1 input
Quadrant Outlet Flows - 4 inputs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the calculation for WPC?

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Where do calculated WPC signals go?

A

RDAS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Describe constrained/unconstrained function of the RDAS power calculation.

A

LPCIS calculates constrained and unconstrained lobe powers at all power levels.
At 3 N_L, CDS switches display from unconstrained to constrained.
1. Unconstrained (<3N_L) - Lobe powers are primarily determined from N-16 system.
2. Constrained (>3N_L) - Lobe powers are primarily determined from the WPC system.
The change is automatic.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Where is the WPC Process Recorder located?

A

WPC Process Recorder is located in the ATR first basement in the WPC Cabinet near the eastern stairwell.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What parameters are displayed on the WPC Total Recorder?

A

Combined outlet flow.
Reactor DT
Reactor Outlet Temp
Total Primary Water Power
Average Inlet Temp.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the Correction Factor for WPC compensating for?

A

The correction factor compensates for changes in density due to temperature.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly