Secondary and UCW System Flashcards
TRA00085
What is the purpose of the SCS?
Remove reactor generated heat and controls PCS temperature.
Where does SCS waste heat go?
Rejected through the ATR Cooling Tower TRA-771
What is the flowrate for SCS?
20000 (2 pump) -34000 (4 pump) GPM
What is the capacity of the SCS?
460000 gallon
What is the temperature of the SCS?
HX Outlet - 120F
Cooling tower basin - 90 F
What is the operating pressure of SCS?
40 psig at pump discharge
20 psig system pressure
Draw SCS
From what loads does UCW receive waste heat?
ATR Experiment Loop Equipment via HDW system
M-42/43 DGs
Relationship between UCW and SCS?
Backups for each other.
Describe SCPs.
4 installed Vertical Deepwell turbine pumps
4160V
350 HP
10000 gpm each
What is the power supply for SCPs?
670-E-1/2
Where are SCPs located?
TRA-671 Secondary Pump House
Where are SCP start/stop switches located?
Started from buttons inside pump house.
What is the function of Temperature Control Valve TCV-1-10?
Controls primary reactor coolant inlet temp by controlling secondary flow through HXs.
What is the power supply for TCV-1-10?
TRA-671 LP-19 Commercial Power
Fail position of TCV-1-10?
Fails as is