Intro to TSRs Flashcards
TRA00243
What is the purpose of the INL Safety Basis List LST-100?
Contains current revision of the TSR and SAR safety bases and a list of the positive USQs at the time the TSR revision is accepted by DOE.
What is the purpose of the ATR Criticality Control List?
Identifies the controls for fissile material storage and handling within ATR.
What is the Purpose of section 1 of the TSR (Use and Applications)?
How to use the TSRs.
What is the purpose of section 2 of the TSR (safety limits)?
The safety envelope that the ATR must be operated within. Violations of limits require the plant to be placed in a safe condition and require analysis to resume operation.
What is the purpose of section 3/4 of the TSR (Operating Limits and SRs)?
Bands within the Safety Limit that the ATR must be operated (more limiting than Safety Limits)
What is the purpose of section 5 of the TSR (Administrative Controls)?
Controls of the ATR that are purely administrative in nature.
What is the purpose of the TSR bases?
More information on each limit or control.
What are the modes of operation?
Seven Modes:
1. Power Ops
2. Low Power Ops
3. Pressurized Standby
4. Pressurized Shutdown
5. Depressurized Standby
6. Depressurized Shutdown
7. Reactor Defueled
What three factors define the mode of operation?
- Safety rod status
- PCS boundary
- EFIS in AUTO or MANUAL
What are the two categories in the TSR for which safety limits are provided?
Core thermal performance
Primary coolant system
What are the four core thermal performance parameters for safety limits?
- Steady-state power
- RV DP (low)
- Reactor inlet pressure
- Reactor coolant flow
What are the three PCS parameters for safety limits?
- PCS pressure
- PCS temperature
- RV DP (high)
What is the difference between section 3 and 4 of the TSR?
Section 3 contains LCOs
Section 4 contains SRs
When do administrative controls apply to ATR?
During all reactor operating conditions unless otherwise stated within the particular AC.
What is the purpose of AC 5.3.2?
Minimum allowable ATR staff for various plant conditions.
What is the purpose of AC 5.4.3/4?
Violation of TSR and response to TSR violations.
What is the purpose of AC 5.7.11?
Requires an ESAP for each experiment.
Lessons learned ATR EFIS Valve failure?
EFIS time response testing being performed.
Portion of testing included valve actuation with n2 bottle backup system.
EFIS valves were actuated for RCR, one valve shut and other remained open with hissing sound.
I&C tech and operator returned to area found LCV-1-7A/B in OPEN position. No pressure in n2 bottle.
Operations went outside of procedure, reset the solenoids and the valve fractured.
Lessons learned from PT-10-6 calibration?
PT-10-6 indicated pressure dropped below min level during maintenance activities. Calibration was performed, and alarm received. Returned to normal after vent was shut. Wrong alternate isolated PT to meet LCO.