TB 130 - New Ladder Pipe Assembly Flashcards

1
Q

What is the new ladder pipe assembly?

A

Akron Brass Company model 1495

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many gpm can the new ladder pipe assembly flow?

A

1000 GPM with a 2” Tip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Seagrave aerial ladder trucks are limited to what of the ladder pipe assembly?

A

800 GPM using the 1 1/2” or 1 3/4” straight tip
Or
500 GPM setting on the spray nozzle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

On the Seagrave truck, members are prohibited from using what?

A

2” Tip
Or
Flowing 1000 GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are the components of the ladder pipe assembly?

A

-Assembly
-2 1/2” In Line Shut-Off
-4” Gate Valve Shut-Off (Cluster)
-2 1/2” Stream Straightener
-Smooth Bore Nozzles (1 1/2”, 1 3/4”, 2”)
-Turbo Master Spray Nozzle (350 to 1000 GPM)
Assigned to random apparatus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The new ladder pipe assembly is longer and therefore requires the ladder to be

A

raised out of the bed and rotated to the right prior to attachment.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The ladder pipe assembly shall be secured to the top

A

two rungs on the fly section

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

To release the lower clamp brake knob, rotate in which direction?

A

Counterclockwise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

To tighten the brake knob, rotate the knob in which direction?

A

Clockwise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How many lock pins should be in place before flowing water?

A

All four ball lock pins

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What shouldn’t be used to secure the Akron 1495 onto the ladder?

A

Ladder Straps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The shut-off should be placed in which position prior to the supply line being loaded?

A

Closed position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

For the shut-off, which direction should you rotate the actuator handle until it stops?

A

Clockwise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Friction loss from which line must be added to the pressures to achieve proper pump pressure?

A

Supply Line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What are the pump pressures for the smooth bore tips?

A

11/2”- 150 PSI (600 GPM)
1 3/4”- 170 PSI (800 GPM)
2”- 190 PSI (1000 GPM)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What are the pump pressures for the Akron Turbo Master Spray Nozzle?

A

350 GPM - 140 PSI
500 GPM - 160 PSI
750 GPM - 180 PSI
1000 GPM - 220 PSI

17
Q

What is the pump pressure for the Hydro-Foam Nozzle?

A

660 GPM - 175 PSI