TB 12 - Automatic Sprinkler System Flashcards

1
Q

The what is by far the most important of all the fire protection devices per NFPA?

A

Automatic sprinkler

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Early detection of fire and effective application of the available what supply are fundamental to minimizing most fire losses?

A

Water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Records show that what percentage of all fires in sprinklers building are extinguished or satisfactorily held in check by the sprinkler system?

A

96%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

NFBU bulletin No. 270 suggest that one of the first fire alarm engine companies responding should lay 2 of what size lines into the fire department connection?

A

2 1/2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Pump operators should deliver what psi to the sprinkler system if nothing showing and when fires showing?

A

100 psi nothing showing

150 psi fire showing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Normally what size hoseline would be sufficient in sprinklered buildings?

A

1 1/2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

In order to properly utilize the potential of sprinklers in the area, it is suggested that companies maintain a list of sprinklered buildings in their district, the info can be obtained from what form which are filed behind what forms in the company files?

A

F-316s filed behind F-173s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Extreme what must be exercised by officers when ordering systems turned off after a fire?

A

Caution

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Who must remain at the control valve so that it can be reopened without delay if needed and until system is put back into service?

A

The fireman ordered to close the control valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Sprinklers delivering water directly over the seat of the fire generally use far less water while doing a better job of cooling and extinguishing than what?

A

Hose lines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Intense what may even prevent hose men from reaching the fire at all?

A

Heat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Junior systems are designed to provide simple, inexpensive protection for light hazard occupancies where not over how many sprinklers are likely to operate?

A

3 or 4 sprinklers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The junior system is connected directly to the service water supply through a what size brass pipe and electric water flow alarm?

A

1”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Is there a fire department connection and drain valve in a junior system?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The junior system itself is a loop of what size copper tubing?

A

3/4” or 1”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What size orifice are the sprinklers in a junior system?

A

1/4” or 3/8”

17
Q

The discharge in a junior system will about how much less water as the standard 1/2” sprinkler system?

A

1/2 as much water

18
Q

Junior systems are distinguished by what extending beyond the center of the deflector?

A

Pintle