TB 21 - Ladderpipe Operation Flashcards
Ladder pipe operations are designed to be performed without the necessity of assigning specific duties other than a few obvious exception such as which positions on the truck?
Apparatus operator and tillerman
For jackknifing, you should jackknife apparatus at what degree from in line and away from direction of ladder extension?
60 degrees
Angle of ladder inclination should preferably be 75 degrees from horizontal and limited to not more than what degree?
80 degrees
What is the aerial ladder extension limits for 100 and 85 foot aerials?
100 feet - 80 feet
85 - 65 feet
Maintain at least what psi on the cylinder pressure gauge to overcome nozzle reaction?
100 psi
For overcoming nozzle reaction, any movement of the hoist control lever will cause the ladder to rise toward what position?
Vertical
To stop the uncontrolled movement of the aerial ladder return the hoist control lever to what position?
Neutral
The nozzleman should immediately raise the nozzle upward or downward to change the direction of nozzle reaction?
Upward
For any excessive movement, a man shall remain at the shut offs, the water shall be turned what gradually to avoid causing a violent whip of the aerial ladder?
On and off
You should do what with the nozzle-member through the intercom before starting any ladder movement?
Notify
To provide protection for the nozzle member, have a firefighter part way up the ladder with what size line loaded preferably supplied from a second source?
1 1/2” or 1 3/4”
An alternative protection line is what size hose from the ground?
2 1/2”
Load the line to the ladder pipe after what degree elevation and as soon as possible?
50 degrees
Seagrave ladder pipes have approval to flow what gpm and what psi?
800 gpm @ 80 psi
LTI apparatus may use the Akron turbo spray nozzle, they shall be limited to what gpm setting when used on the ladder pipe?
750 gpm