Standby Liquid Control (SLS) Flashcards

1
Q

What supplies air to the SLC hydro pump?

A

Service Air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the capacity of 1 SLC pump?

A

45 GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What must happen 1st before a SLC pump starts?

A

The MOV1 suction valve must open 1st.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What does 2EHS*MCC102C send power to?

A

MOV1A, P1A, VEX3A (squib vlv), MOV5A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What does 2EHS*MCC302D send power to?

A

MOV1B, P1B, VEX3B (squib vlv), MOV5B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What do the lights do when the squib valve is fired?

A

GO OUT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What does it mean if discharge pressure of the SLC pump is 1600#

A

No flow path.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What pressure is the SLC pump relief valve set at?

A

1600#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Can divisions be crossed with the SLC hydro pump?

A

NO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What happens to SLC tank level indication on a loss of IAS?

A

Fails Low

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What happens to the squib current meter after being fired?

A

The current meter goes downscale

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What happens when the SLC tank is empty?

A

Trips the SLS pumps and closes the MOV1s. This is from level received from RRCS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What percentage must the sodium pentaborate solution be?

A

13.6% at 1600 gal
to
14.4% at 1530 gal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What are the operating parameters for the SLC tank mixing heater

A

Manual
45kw

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What are the operating parameters for the SLC tank operating heater

A

Automatic
10kw

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

what happens when there is only one suction source with both pumps running

A

Still get full flow of approx 86 gpm.

17
Q

What must happen to WCS when SLC is initiated and why?

A
  1. Isolate
  2. Running WCS will reduce the boron concentration.
18
Q

What temperature is maintained in the SLC tank from the 10kw operating heater?

19
Q

What is needed for a SLC tank low level SLC pump trip?

A

Four level transmitters (2SLS*LT6A, B, C, D) provide SLS storage tank ‘zero’ level signals to RRCS. RRCS trip units use these signals to trip running SLS pumps (or prevent pump start) if tank level is low. The ‘A’ and ‘C’ transmitters input to RRCS Division I; the ‘B’ and ‘D’ transmitters input to Division II. Need BOTH from a division to trip its associated pump. (A & C Trip ‘A’ Pump, B & D Trip ‘B’ Pump).