Cond Demins (CND) Flashcards
1
Q
How much Feedwater flow is passed through the Cond Demins?
A
2/3 of total feedwater flow (1/3 is from 4th stage heater drain pump)
2
Q
What happens to inlet, outlet and transfer valves on a loss of Instrument Air?
A
- Inlet and Outlet valves fail As-Is
- Transfer valves fail closed
3
Q
What cannot be done with a loss of Service Air?
A
Cannot transfer resin
4
Q
What happens to isolation valves on a loss of power?
A
Isolation Valves fail As-Is
5
Q
During normal operations, what are the Cond Demin system limitations?
A
- D/P: <= 55psid with Max of <=60 psid
- Flow: <3300 gpm with max not to exceed 3500 gpm
- Design temperature: 140F
6
Q
When should Cond Demins be removed from service?
A
System D/P: < 35psid
Flow: <2000gpm
7
Q
What is used for slucing resin?
A
Condensate and Service Air