Cond Demins (CND) Flashcards

1
Q

How much Feedwater flow is passed through the Cond Demins?

A

2/3 of total feedwater flow (1/3 is from 4th stage heater drain pump)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What happens to inlet, outlet and transfer valves on a loss of Instrument Air?

A
  1. Inlet and Outlet valves fail As-Is
  2. Transfer valves fail closed
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What cannot be done with a loss of Service Air?

A

Cannot transfer resin

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What happens to isolation valves on a loss of power?

A

Isolation Valves fail As-Is

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

During normal operations, what are the Cond Demin system limitations?

A
  1. D/P: <= 55psid with Max of <=60 psid
  2. Flow: <3300 gpm with max not to exceed 3500 gpm
  3. Design temperature: 140F
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When should Cond Demins be removed from service?

A

System D/P: < 35psid
Flow: <2000gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is used for slucing resin?

A

Condensate and Service Air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly