Low Pressure Core Spray (CSL) Flashcards

1
Q

Function of LPCS

A

Sprays each bundle with sufficient water to prevent excessive cladding temperature following a DBA LOCA without the aid of other LP ECCS.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the initiation signals for LPCS?

A

L1
1.68#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the discharge flowrate and pressure of the LPCS pump

A

6350 gpm
290 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the Power Supply for the LPCS pump?

A

DIV 1 AC
(DIV 1 DC for instruments and controls)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How do the Unit Coolers affect OPERABILITY of LPCS?

A
  1. One Unit Cooler down - OPERABLE.
  2. Two Unit Coolers down - INOP and declare associated GTS INOP
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What happens to *FV114 (LPCS Test Return Valve) on initiation signal?

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Where does a line break indication occur in the system for LPCS?

A

Break between RPV wall and Core Shroud.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the Open Permissive for MOV104

A

88 psid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is Discharge Pressure for CSL Pump?

A

450#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When does injection to the RPV actually occur?

A

When pump discharge pressure is greater than vessel pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What are the features of MOV104 LPCS injection valve?

A
  1. No auto closure
  2. strokes with Overload with initiation signal.
  3. Throttleable if manually stroking
  4. Amber light when manually closed.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What actions are taken to secure the pump

A
  1. PTL
  2. Shut MOV104 (injection valve)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the purpose of the SCM* panels

A
  1. Provide power to postage stamps
  2. If one of these breakers is open, the system will still function but postage stamp will not light.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is CSL initiation logic power supply?

A

BYS*PNL201A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When does min flow valve MOV107 close?

A

> 1200gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What happens on a Thermal Overload for the min flow valve MOV107?

A

Actuates an annunciator but does not interrupt valve motion.

17
Q

Does LPCS injection valve open in manual override?

A

With a LPCS logic initiation signal present and the injection valve manual override sealed in the LPCS injection valve will not auto open.