Seismic Monitoring Flashcards
What Earthquake could reasonably be expected to affect NMP?
Operating Basis Earthquake
What is OBE vibratory ground motion?
0.075g
What Earthquake is the maximum in which the plant can still safely shutdown?
Safe Shutdown Earthquake (SSE)
What is Safe Shutdown Earthquake (SSE) vibratory ground motion?
0.15g
What is the setpoint of the seismic switch?
0.075g
What is the setpoint of the seismic trigger?
0.01g
What happens on a Seismic Trigger?
Alarm, indication Black to White, Tapes Start.
Where is teh event indication light?
PWRS 1
What do the amber lights indicate?
OBE level, 0.075g
What do the red lights indicate?
SSE level, 0.15g
What is the purpose of seismic monitoring?
Monitors and records the input motion and the plant response in the event of an earthquake.