Radiological Waste (LWS) Flashcards
What is considered Low Conductivity Waste?
(<50umho/cm and/or <400ppb TOC)
What is considered High Conductivity Waste?
(>50umho/cm and/or >400ppb TOC)
What is the Radwaste Computer Power Supply?
UPS1A
What is the Power Supply of the Surge Tank Pumps?
US9
What is the Power Supply of the Phase Separator Pumps?
MCC014
What are the liquid rad waste pump trips?
- Seal Water Trouble
- Low Tank Lvl
- surge tanks <11%
- All others <2%
What are the Phase Separator trips?
- Low level @ 9% if in DECANT
- Low level @ 86.3% if in RECIRC
- Low flow (7gpm, 10 sec TD)
What is the Equipment Exhaust Fan trip?
Low flow, <1500 cfm (35sec TD)
What is the source of seal water to the Phase Separators in Rad Waste?
Condensate
What is the purpose of the Liquid Rad Waste System?
Collects monitors and processes for reuse or disposal all potentially radioactive liquid wastes.
What is the purpose of the Solid Rad Waste System?
Collects, monitors, processes, packages and provides for temporary storage of radioactive materials prior to disposal.