Radiation Monitoring (RMS) Flashcards
Where are WRGMS monitoring systems located?
One for the Main Stack
One for the Rx Bldg/Rad Waste
What is the Rad setpoint for Rx Bldg Ventilation
1.7X10E-3uCi/ml
What is the Rad setpoint for Main Control Room Air Intake
5.92X10E-6uCi/ml
(Rad Monitors only start their own division, NOT BOTH)
What shows you a refuel floor alarm?
Klaxton and red light
What rad monitor is used when HVR is isolated?
RE229
What is rad monitor SWP146A used for?
DIV I Discharge Header and Fish pump ( potential release points)
How long do we have with all DW Rad Monitors INOP?
7 days
For radiation monitors, what must be active to sound alarms?
The alarm screen.
For rad monitors, what happens on a loss of UPS2A?
SFT ‘A’ starts
What flow are CAB13s INOP?
> 40scfm
What Rad Monitors will be the first to see a small fuel pin leak?
Offgas Rad Monitors RE 13s