SR- Solid Radwaste Flashcards

1
Q

[SR]

[[SR] Purpose?

A

Handles & packages:
concentrated [LR],
spent resins,
disposable filters,
and (DAW) dry active waste

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

[SR]

How does the [SR] handle spent resin? (3)

A

1-Resin is sluiced to a liner (high integrity container (HIC)),
2-dewatered,
3-and dried with the resin drying system.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

[SR]

What tank can be used to flush and decontaminate [SR]?

A

RMWT - Reactor Makeup Water Tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

[SR]

What flushes [SR] after volume reduction?

A

DS (Domestic Water)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

[SR]

If an alarm is received in RW, how long before it is received in the Main CR?

A

-5 minutes
(if not acknowledged in RW CR)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

[SR]

Which [SR] Spent Resin Tank normally receives spent resin from [LR] adsorption bed and mixed bed demineralizers?

A

Low Activity Spent Resin Tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

[SR]

What resin does [SR] High Activity Spent Resin Tank normally receive?

A

-[CH] & [PC]
- Spent resin from [CH]
(purification, deborating and pre-holdup ion exchangers)
- Spent resin from [PC] cleanup Ion Ex.

  • Resin >500 mr/hr
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

[SR]

Where is dilution water injected into the [SR] Spent Resin Tanks?

A

-At the bottom head near the resin removal line
-facilitate dilution and mixing of the resin as the slurry enters the resin outlet pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

[SR]

How is resin removal accomplished in the Spent Resin Tanks?

A

-By a line inside a line, which provides sluice water in the outer pipe area through a Johnson screen to the inner pipe area, near the tank bottom. This transports resin with an educator effect as the water/resin exits the inner pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

[SR]

What connections are provided as a backup method for fluidizing the spent resin tank beds in the SR system?

A

Air and nitrogen connections

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

[SR]

What is the purpose of the SR Resin Transfer/Dewatering Pump? What kind of pump is it?

A

Transfers spent resin from various ion exchangers/demineralizers to the high and low spent resin tanks

Also transfers the contents of the spent resin tanks to the resin drying system

progressing cavity positive displacement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

[SR]

Why is the fluid discharged from the SR Resin Transfer/Dewatering Pump free of pulsations or vibrations?

A

It does not use pistons or valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

[SR]

What system supplies the mechanical seal to the SR Resin Transfer pump?

A

RWMT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

[SR]

What would cause the SR Resin Transfer pump to stop? Where can this pump be controlled from? Location?

A

Low suction pressure and electrical overload condition

RW control room, solidification panel and local handswitch

100’ RW building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

[SR]

When the Resin Transfer pump starts, why is a signal sent to deenergize solenoid valve SRN-HY-402?

A

Opens valve SRN-HV-402, which supplies reactor makeup water to pump seals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

[SR]

Following a loss and restoration of power to the Resin Transfer pump, how is the pump restarted?

A

Manually

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

[SR]

What is the purpose of the Vendor system?

A

Designed to convert plant evaporator concentrates into a non-dispersible form, which is packaged in 55 gallon drums for disposal

18
Q

[SR]

What is the purpose of the Radioactive Filter Transfer Cask?

A

Used to shield highly radioactive filters while being transported from the filter vault(120’ aux building) to a disposable container (RW building)

19
Q

[SR]

How thick is the lead shielding in the SR Filter Transfer Casks?

A

8 inches

20
Q

[SR]

What are some of the requirements on using the Disposable Containers in the SR system?

A

Must be chemically compatible with the waste material so that the waste material does not adversely affect the integrity of the container

Container needs to have the proper dewatering internals system consistent with the waste being processed

21
Q

[SR]

What boxes are used for DAW storage and transport?

A

Connex boxes

22
Q

In the SR system, what does NH power?

A

Spent resin transfer/dewatering pump and motor space heater

solidification panel

23
Q

What does NK power?

A

Control panel annunciators

24
Q

What other system inputs does SR receive?

A

liquid waste from LR (reduced, vacuum dried, put into 55 gal. drum or HIC)

resin from LR, CVCS and PC (sluiced to a liner or HIC, dewatered and dried in resin drying system)

disposable solid radwaste generated by plant operation

25
Q

How does Ancillary buildings HVAC interface with SR?

A

Dry Active Waste Processing and Storage facility HVAC

26
Q

What does [IA] do for [SR]?

A

AOVs

27
Q

What are the differences between the HASRT and LASRT? Where are they located?

A

HASRT has more shielding around it

100’ RW building

28
Q

In the SR system, how is level tracked in the spent resin tanks?

A

spreadsheet based on calculated inputs and outputs

29
Q

What are the major components of the resin drying system?

A

waste transfer system

fillhead

piping skid

chiller

blower skid

control panel

humidity monitoring system

remote video system

30
Q

In the SR resin drying system, what is the waste transfer system?

A

high pressure flexible hoses and pneumatic ball valves connecting the spent resin tanks transfer piping to the fillhead

31
Q

In the SR resin drying system, what is the fillhead?

A

provides the connections between the waste transfer system and the disposable container

connects to the piping skid to remove excess water from the container

connects to the blower skid for incoming dry, hot air for drying process

also contains the video camera, electrical connections, pressure switch and cooling air supply

32
Q

In the SR resin drying system, what is the piping skid?

A

skid with hose connections for processing powdered and bead resins, entrainment separator tank to collect the removed water, and an air driven pump to remove the water from the separator tank

33
Q

In the SR resin drying system, what is in the entrainment separator tank that condenses the moisture in the air that is pumped through the resin bed during the drying process?

A

refrigeration coils

34
Q

In the SR resin drying system, what is the chiller unit for?

A

contains a compressor, hoses and cooling fan for cooling the separator tank

35
Q

In the SR resin drying system, what is the blower skid?

A

a blower to recirculate the air trough the drying system components

oil separators and filters to remove oil and particulates from recirc air

36
Q

In the SR resin drying system, what is the humidity monitoring system?

A

measures the humidity of the entrainment separator tank

37
Q

In the SR resin drying system, what is the remote video monitoring system?

A

camera mounted to verify level during resin transfer with light dimmer control

38
Q

Concerning the SR resin drying system waste container, what do you need to beware of? What is done to solve this issue?

A

exothermic reactions

flood the container with plant sourced water

39
Q

What is the most important feature of the SR resin drying system?

A

ability to remotely stop resin flow to prevent over filling

40
Q

Concerning the SR radioactive filter transfer cask, the monorail hoist grapple hook design provides a positive attachment system. How does that work? Where is the hoist mounted?

A

remains locked under the weight of the filter cartridge

120’ aux. building ceiling

41
Q

Why would AO’s need to go into the DAWPS facility?

A

fire alarm activated, U# AO to investigate all areas inside, including the offices and change area, the Storage and processing area RCA