[ED] - Extraction Steam and Drains Flashcards
[ED]
[ED] purpose?
Extraction Steam & Drains
Preheats CD and FW prior to feedwater entering the S/Gs to increase plant efficiency
[ED]
What provides steam to #4 LP feedwater heater during startup?
Extraction Steam & Drains
[AS]
[ED]
What water system makes-up to the bottom of the ED blowdown stack?
Extraction Steam & Drains
[DS] Domestic Water
[ED]
What is the purpose of the ED blowdown stack?
Extraction Steam & Drains
-collection point for steam traps, HP heater relief valves and miscellaneous [AS] header drains
Aux Steam
[ED]
When is [DS] added to [ED] blowdown stack?
What occurs if [DS] is OOS?
(Domestic Water)
Extraction Steam & Drains
If temp of water >150F
Steam will come out of the blowdown stack and north Condenser sump
[ED]
GA-N2 & ED?
Extraction Steam & Drains
Supplies Nitrogen blanketing of FW Heater Shells & HDTs during long term shutdown operations
Feedwater
Heater Drain Tanks
[ED]
[IA] & [ED]?
2
Extraction Steam & Drains
[MT] control system uses [IA] in Turbine Critical and Non-Critical Relay Dump Valves (provide a signal to control BTVs)
For use all [ED] AOVs
Main Turbine
Bleeder Trip Valves
Instrument Air
Air Operated Valves
Extraction Steam & Drains
[ED]
How are BTV’s affected by a loss of [IA]?
Extraction Steam & Drains
Bleeder Trip Valves
go partially closed (Lose open permissives)
remain open due to [ED] flow
Bleeder Trip Valves
Extraction Steam
Where are the Heater Drain Pumps powered from?
Extraction Steam & Drains
‘A’ from NBN-S02
‘B’ from NBN-S01
[ED]
Where does seal water for each Heater Drain Pump come from?
Extraction Steam & Drains
Condensate Header
(375-500 psig)
[ED]
What positions the Heater Drain Pump mini-flow valves? When will it close? What controls the position of the heater drain pump discharge valve?
Extraction Steam & Drains
Heater Drain Pumps flow transmitter
as the unit comes up in power and more extraction drain flow is available
heater drain tank normal level control valve
[ED]
What signals stop the Heater Drain Pumps?
3
Extraction Steam & Drains
HDT lo-lo level alarm
Heater Drain Pump low flow after a time delay
Electrical protection signal
[ED]
Where are Heater Drain Pumps located?
What allows one heater drain pump operation?
Extraction Steam & Drains
TB 100’ (West of Main Feed Pumps)
Open suction
and vent cross-tie between HDTs
Heater Drain Tanks
[ED]
Why doesn’t #5 FW Heater have a level control system?
Extraction Steam & Drains
No drain cooler region
Drains directly to the HDT
Heater Drain Tank
[ED]
Which LP FW heaters have four inlets?
How many do the others have?
Extraction Steam & Drains
1 & 2
3 & 4 have 1 inlet each
Which feedwater heater has an input from S/G blowdown system?
Extraction Steam & Drains
3
[ED]
What is the purpose of the BTVs? Which feedwater heaters have BTVs?
Extraction Steam & Drains
Bleeder Trip Valves
Prevent [MT] reverse steam flow (overspeed) on Turbine Trip
3-7
Main Turbine
[ED]
What on the BTVs assists disc opening with min differential steam pressure?
Extraction Steam & Drains
Bleeder Trip Valves
Balance Arm device
What happens the Bleeder Trip Valve test valve actuates?
Extraction Steam & Drains
air pressure across the operator piston is equalized to allow partial closing of valve disc by spring force
Why are there 2 BTVs on #4 FW heater extraction line?
Extraction Steam & Drains
Feedwater
there is enough energy in #4 by itself to cause an overspeed trip
[ED]
Which level control valves are reverse acting in [ED]?
Extraction Steam & Drains
All high level CVs and #1 LP heater normal level CVs
Low Pressure
Control Valves
At what air signals are the reverse acting valves full open and full closed in the ED system?
Extraction Steam & Drains
Full open with 3#
Full closed with 15#
(Direct acting is the complete opposite)
What happens upon a hi-hi signal in a HP feedwater heaters?
Extraction Steam & Drains
Isolates extraction steam
Closes the normal level control valve of the preceding heater
Opens the affected heater’s motor operated extraction steam line drain valve
In addition, for the HP heaters, the 1st and 2nd stage reheater drain tank vents isolate from the affected heater and vent to the main condenser
What happens upon a hi-hi signal in a LP feedwater heaters?
Extraction Steam & Drains
Isolated entire LP heater train by closing the heater train isolation valves
Isolated extraction steam to #3 and #4 heaters
Opens the extraction line solenoid operated drain valves for #3 and #4 heaters