GR- Gaseous Radwaste Flashcards
[GR] purpose?
- Collects and processes high/potentially radioactive waste gases (Primarily Hydrogen & Nitrogen) generated in plant in an oxygen free system to permit decay of short-lived isotopes.
- Keeps exposure of onsite and offsite personnel within acceptable limits
[GR] Components?
gas surge header,
waste gas surge tank,
two waste gas compressors,
three waste gas decay tanks and associated piping
[GR] Flowpath
Waste Gas Surge Header
Waste Gas Surge Tank
Filter
Compressor - (2 parallel/redundant)
Compressor Discharge Header
Waste Gas Decay Tanks
AOV Isolation Values (2)
Gaseous Discharge Filter
Flow Element,
RU- 12
Flow Control Valve
RW Exhaust
plant vent (w/ additional radiation monitors)
RU - 1
[GR]
RW CR [GR] instrumentation power?
NN
[GR]
Waste Gas Compressors power? Location?
NH
140” RW building
[GR]
[GA - N2] interaction with [GR]?
Nitrogen for the initial system purge
- subsequent purges to allow for maintenance
- Auto Purge - O2 Analyzer hi alarm in surge header
[GR]
What causes gas surge header isolation valves to auto close?
Where does the relief valve on this header discharge to?
CIAS
RW Exhaust
[GR]
Gas Surge header MOV isolation valve power?
PH
[GR]
Gas surge header solenoid operated isolation valve power?
PK
[GR]
Gas Surge Tank purpose?
Absorbs fluctuations in system gas volume to minimize compressor operating time
[GR]
Design temperature of Gas Surge Tank plastic liner?
200 F
[GR]
Gas Surge Tank location?
RW 140’
[GR]
Gaseous Radwaste compressor purpose?
- Pump LP gas from surge tank to decay tanks.
-Auto controlling surge tank pressure
[GR]
In auto, which compressor will start if there is a high surge tank pressure and the mode selector switch is in:
A-lead, B-STNBY
“A” Compressor
[GR]
What starts both compressors in auto ?
Hi-Hi surge tank pressure
[GR] Decay Tanks Purpose?
-holding area for waste gas to undergo radioactive day prior to atmospheric discharge.
[GR]
What automatically causes Decay Tank Discharge Header isolation valves (34A/34B) to close? (4)
What else closes?
Is it auto or manually reopened?
1- Low D/P of [HR] exhaust fan A & B
2 - High waste gas discharge flow
3 - High Rad level
4 - High Pressure - rad monitor supply line
Solenoid AOV flow valve FV-33 causing it to close.
Manually
[GR]
OOS when?
Surge Header Isolation valve Valve (GRN-V002) is closed
OR
All surge header inputs are red tagged closed
[GR]
Oxygen Analyzer Hi-Hi alarm set point? What else occurs?
3.75%
Isolates [GR] system by stopping the compressors and starts auto dilution of with nitrogen
[GR]
Nitrogen Dilution is secured when?
25 psig (which should reduce oxygen concentration by 50%)
[GR]
What powers auxiliary relays in the RW Control Panel?
NK
[GR]
The 2” gas surge header receives emissions from what sources? (6)
RDT
CNTMT Refuel failed fuel detector vent
Dry Sipping Aux Pump
Gas Stripper
VCT and relief
Oxygen Analyzer return
How does [GR] interface with [HR]?
high activity portion of GR discharges to the HR system
low activity aerated waste gas is also vented from selected equipment
What is the purpose of the GR waste gas compressors? What cools them?
pump low pressure gas from the waste gas surge tank to the waste gas decay tanks for holdup prior to release
NC