NC- Nuclear Cooling Flashcards
[NC]
Pump capacities
How many are normally in operation?
-2 pumps in parallel
-100%
-1/2
100-110 psig (17,500 gal/min)
[NC]
[NC] Pump power supply?
[NB]
‘A’ – NBN-S01 ‘‘B’ – NBN-S02
[NC]
What auto starts standby [NC] pump?
Pump discharge header pressure
79 psig
[NC]
How would the Control Room know if [NC] standby pump auto started?
Amber Light (Lit) in CR
[NC]
Which side does [PW] flow through on [NC] Hx (Tube or Shell?)
Tube Side
[NC]
To shift to standby Hx, what actions must be performed?
Vent on-coming Hx on both shell and tube side to ensure a filled condition.
[NC]
How do we manually adjust [NC] temperature?
What temperature band?
Temp Up - Open Flow Bypass Valve (bypassing Hx)
Temp Down - Close Flow Bypass Valve (more flow to Hx)
75-105*F
[NC]
Which system of the [NC] Hx, is at a higher pressure?
[PW]
to prevent potentially contaminated nuclear cooling water leakage into the PW system and environment
[NC]
[NC] Surge tank purpose? (4)
-Absorb fluxtuations in system due to temperature changes
-NPSH for [NC] pumps
-detecting leakage
-Location for adding makeup water
[NC]
Surge Tank location?
Capacity?
AB Roof (NE)
1000 gal
[NC]
Makeup water to [NC]?
What is it inserted into?
[DW] Demineralized Water
Surge Tank
[NC]
Backup makeup water source to [NC] ?
Where are the valves to align this back up make up source?
[CM] Chemical Waste System
100’ aux building, south wall
[NC]
Purpose of nitrogen in the Surge tank?
Cover gas -oxygen exclusion for corrosion
5 psig
[NC]
How are chemicals added to the system with th Chem Add Tank?
D/P with [NC] pump flush
[NC]
The NC Chem Add Tank is normally isolated. Besides adding chemicals, when would we align flow through it and why?
When Cold Weather Protection is in effect to prevent freeze damage
[NC]
What does RU-6 monitor?
Location?
[NC] in-leakage from the contaminated systems it cools
Turbine Building North Yard
Next to the [NC] pumps
[NC]
Letdown Hx TCV purpose?
Control [NC] flow thru Hx to auto regulate LDHx outlet temp setpoint by CR
NCN-TV-223 - (usually 120F) - AB 110’ above LDHx
[NC]
Why, as AO’s, should we worry about the flow of NC through the LDHX? What is the maximum NC flow rate through the letdown HXs?
Because it controls Letdown temperature and could ultimately affect reactivity
1500gpm
[NC] 10
What are the 8 Priority heat loads?
Normal Chillers
Nuclear Sample Coolers
CEDM Normal ACUs
[RC] RCP
Seal coolers
HP coolers
Thrust Bearing Coolers
Motor Air coolers
Lube Oil Coolers