Solid Radwaste Flashcards

1
Q

[SR]

4 subsystems?

A

-Spent Resin Transfer
-Wet Waste Processing
-Dry Waste Disposal
-Filter Handling & Disposal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

2 Solid waste waste management buildings?

A

DAWPS -Dry Active Waste Processing & Storage
-Low Level Radioactive Material Storage Facility

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

DAWPS - Dry Active Processing & Storage facility function?

A

-centralized location to handle,process,package,& store of radioactive trash

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Low Level Radioactive Material Storage Facility provide ?

A

Provides interm storage capacity for radioactive material prior to reuse,shipment for processing or disposal, or transfer to other licensees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

[SR]

Where does [SR] receive Ion Exchanger Resin from ?

A

-LR system
-Chemical & Volume Control system
-Fuel Pool Cleanup

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

[SR]

How is Spent Resin Processed ?

A

Spent Resin is sluiced to a liner or High Integrity Container(HIC), then dewatered & dried with Resin Drying system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

[SR]

What system do the Local Control panels for SR provide centralized control of equipment in SR system ?

A

-Radwaste Control Room Instrument Cabinet
-Solidification panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

[SR]

What remote operated equipment can be control from SR Control Panel ?

A

-Resin Trasnfer/ Dewatering pump
-RMW for resin transfers & system flushing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What happens in Main Control Room if there is an alarm inside the Radwaste Control Room ? What is the time delay for the trouble alarm ?

A

-There will be a trouble alarm in the Main Control room
-If alarm in Radwaste Control Room is acknowledged in 5mins, then no trouble alarm in Main Control Room

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What’re the Spent Resin Tanks used for ?

A

1 High Activity & 1 Low Activity are provided to holdup spent resin for decay prior to Wet Waste processing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

[SR]

What kind of resin does the High Activity Spent Resin Tank have ? What Ion Exchangers does it normally receive spent resin from ?

A

-Receives any resin that exceeds 500mr/hr
Spent Resin:
-CH Ion Exchangers
-PC Cleanup Ion Exchangers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

[SR]

Where does the Low Activity Spent Resin Tanks normal receive spent resin from ?

A

Receivers Spent resin from:
-LR Adsorption Bed & Mixed Bed Demineralizes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

[SR]

How is resin removal accomplished ? What is backup to fluidize spent resin tank beds ?

A

-Line inside a line which provides sluice water & sluices it out
-Air & Nitrogen are backup methods for Fluidizing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

[SR]

What is the Spent Resin Transfer/Dewatering Pump used for ?

A

-Used to transfer resin from Aux.Building & Radwaste Building Ion Exchangers to Spent Resin Tanks
-Transfers contents Spent Resin Tanks to Resin Drying system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the Resin/Dewatering Pump powered from ?

A

Powered from NH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What supplies seal water to Resin Transfer/Dewatering pump?

A

RWT - Reactor Makeup Water

17
Q

What cautions are there with spent resin?

A

-exothermic reactions
in waste container during drying of spent resin

18
Q

In event of Exothermic reaction what should you do ?

A

Flood the container with water using the same waste transfer hose so you don’t have to disconnect the hose until process is complete

19
Q

What is the Radioactive Filter Transfer Cask used for?

A

Used to shield highly radioactive filters from filter vault to disposable container

20
Q

How many inches of lead is placed between two shells ?

A

8inches of lead is provided for shielding between two shells

21
Q

What’re the disposable containers ?

A

-Carbon Steel Drums
-Highly Integrity Containers
-Liners

22
Q

What is Dry Active Waste compose of ?

A

-Rags
-Paper
-Plastic
-Rubber
-Wood
-Glass
-Concrete
-Metal

23
Q

What is the three compartments the DAWPS facility broken up into ?

A

-Storage Area
-Processing Area
-Offices & change area